![background image](http://html1.mh-extra.com/html/pentair/intelliflo-5pxf-vsd/intelliflo-5pxf-vsd_installation-manual_1524899026.webp)
24
AntiFreeze
This feature allows you to set a speed (450 RPM -3450 RPM) that will run when the pump goes into
anti freeze mode. The temperature level that you wish anti freeze mode to start can also be set.
IMPORTANT NOTE: This feature is for protection of the pump. Do not depend on the antifreeze feature
for freeze protection of the pool. Certain situations could cause the pump to sense a different temperature
than actual air temperature. Your automation systems air temperature sensor should be used to sense
actual temperature. For example, if the pump is located indoors, the temperature of the room does not
indicate the outdoor temperature. The pump does not sense the water temperature.
To access the AntiFreeze menu:
1. Check that the green power LED is on.
2. Press the
Menu
button. “Settings” is displayed.
3. Use the
Down
arrow button to scroll to “AntiFreeze”.
4. Press the
Select
button. The factory default is AntiFreeze “Enabled“.
5. To disable AntiFreeze. Press the
Select
button, “Enabled” will highlight.
6. Use the
Up
arrow button. “Disabled” is displayed.
7. Press the
Enter
button.
To program AntiFreeze when enabled:
8. Press the
Down
arrow button.
“Set Speed” is displayed. The factory default is 1000 RPM.
9. Press the
Select
button to change the setting. The cursor will highlight the first column
(ones).
10. Use the
Up
or
Down
arrow button to select 450 - 3450 RPM.
11. Press the
Enter
button to save the setting.
12. Press the
Down
arrow button. “Pump Temperature” is displayed.
This is the temperature the
pump will activate AntiFreeze. The factory default is 40° F (4.4° C).
13. Press the
Select
button to change the setting. The cursor will highlight the first column
(ones).
This setting can be changed from 40° F to 50° F (4.4° C - 10° C).
14. Press the
Enter
button to save the setting. Note: To cancel any changes, press the
Escape
button to exit without saving.
15. Press the
Escape
button to exit.
English
Summary of Contents for INTELLIFLO 5PXF VSD
Page 235: ...233 NOTES...
Page 236: ...234 NOTES...
Page 237: ...235 NOTES...
Page 238: ...236 NOTES...
Page 239: ...237 NOTES...
Page 240: ...238 NOTES...
Page 241: ...239 NOTES...
Page 242: ...240 NOTES...