23
Priming
(Continued)
To access the Priming menu:
1. Check that the green power LED is on and press the
Menu
button. “Settings” is displayed.
2. Use the
Down
arrow button to scroll to “Priming”.
3. Press the
Select
button. The factory default is set to priming “Enabled“.
4. To disable priming, press the
Select
button.
5. Use the
Up
arrow button. “Disabled” is displayed.
6. Press the
Enter
button.
7. Press the
Down
arrow button. Screen will read “Max Priming Time”. The factory default is
set to 11 minutes.
8. Press the
Select
button to change the setting. The cursor will highlight the minutes column.
9. Use the
Up or Down
arrow button to change the time from 1 minute to 30 minutes.
10. Press the
Enter
button to save the setting.
11. Press the
Down arrow
button. The screen will read “Primed Sensitivity”. The default for
this setting being “1”.
12. Press the
Select
button to change the setting. The cursor will highlight the number.
13. Use the
Up or Down
arrow button to change the time from 1% to 100%. Increasing the
number makes the Priming less sensitive.
14. Press
Enter
to save.
15. Press the
Down arrow
button. Screen will read “Priming Delay”. The default for this
setting is 20 seconds.
16. Press the
Select
button to change the Setting.
17. Use the
Up or Down arrow
button to change the setting from 1 second to 10 minutes.
Caution: Increasing the Priming Delay causes the pump to stay in the priming mode longer.
18. Press the
Enter
button to save the setting.
Note:
To cancel a change, press the Escape
button instead of the
Enter
button to exit without saving.
19. Press the
Escape
button to exit.
Disable Priming Feature on the Pump
When the IntelliFlo
®
VSD pump is connected to an automation control system, the priming feature
on the pump cannot be disabled by the external automation control system only. If the IntelliFlo
®
pump is connected to an automation control system and priming is not desired, disable the priming
feature on the pump.
To disable priming with an automation control system:
1. Temporarily disconnect the RS-485 communication cable.
2. Open the LCD screen lid to disable priming on the pump. Press the
MENU
button, use the
arrow
buttons to scroll and select “Priming”, then select “Disabled” (the factory default is
set to “Enabled”). Press
Escape
to exit the menu.
3. Once priming is disabled, reinstall the RS-485 communication cable.