KEYPAD
The keypad programs the Pentair Pentek Intellidrive® Constant
Pressure Pump Controller, monitors the status of the pump, and
displays faults if they occur. Each button has a unique function
(Figure 2).
The LCD display shows a text display of the status of the
Intellidrive’s operation. Other LEDs light up to indicate when
certain buttons are pressed or certain events occur.
FAN
The Intellidrive uses a thermostatically controlled internal
fan which operates automatically when necessary to cool the
Intellidrive components.
GENERAL INFORMATION
Figure 2 - Keyboard Functions
6007 0412
Stops the motor.
Power is ON to Intellidrive.
A fault has occurred.
Selects menu items and confirms
numeric value changes.
Displays Intellidrive's current operating
condition and changes display
parameters.
Changes display to previous screen.
Intellidrive is in Warning Mode (TPM);
refer to Troubleshooting section.
Changes internal pressure setpoint from
15 PSI to transducer max -3PSI
(default is 60 PSI).
Runs Intellidrive (with no pressure control) to
allow installer to pump out well.
Up and down arrows scroll through menus
and change numeric values.
Toggles between English, Spanish, and
French (default is English).
Resets fault that stopped Intellidrice/pump.
With code, locks and unlocks password
protected keys.
Left and right arrows move cursor.
Shows last 15 faults.
Checks for line fill, then starts pump in
constant pressure mode.
Views and changes parameters.
TRANSDUCER
The Intellidrive uses a 4-20mA, 0-100 PSI pressure transducer
to control motor speed. Settings may be changed to use a max
300 PSI transducer.
The transducer (Fig Refer to pump’s Owner’s Manual and the
National Electrical Code for proper wire size.
Each carton contains:
Pentek Intellidrive Variable ure 1) senses pressure in the pipe
and converts it to an electrical signal. The Intellidrive senses
and processes the signal in the PID (Proportional,Integration,
Derivative) Control.
When operating in AUTOSTART mode, the Intellidrive
increases and decreases the speed of the pump motor as
needed to maintain constant pressure in the piping system.