Pentair Hydromatic Installation And Service Manual Download Page 9

9

Fiberglass  

Simplex

Parts List

ORDERING REPLACEMENT PARTS: 

Product improvements are made from time to time. The latest part design will be fur nished as long as it is 

in ter change able with the old part.When ordering re place ment parts, always furnish the fol low ing information: 

(1) pump serial num ber, (2) pump model and size, (3) part description, (4) part number, (5) quan ti ty required, 

and (6) shipping instructions.

Ref.

No.

Part 

No.

Part 

Description

Qty.

1

52632-000-7

Pump,HPD200M2-4, sewage grinder, 

230V/60 Hz/1ø,  

Positive Displacement

1

52776-020-7

Pump, HGRS200M22, sewage grinder, 

230V/60 Hz/1ø, Centrifugal

1

2

14887-003-1

Stand for HPD200 Positive

Displacement Pump

1

27078B005

Stand for HGRS200 Centrifugal Pump

1

3

12870-015-1

Junction Box, NEMA-6, 2" NPT

1

4

14595-320-1

Float control, pump, 20' cord

1

5

21813A322

Float control, alarm, 20' cord

1

6

22470B005

Float control bracket

1

7

23901D303

Basin, 24" x 48", Fiberglass

1

23901D301

Basin, 24" x 60", Fiberglass

1

23901D304

Basin, 24" x 72", Fiberglass

1

23901D306

Basin, 24" x 84", Fiberglass

1

23901D308

Basin, 24" x 96", Fiberglass

1

8

21936D200

Basin Cover, Structural Foam

1

9

24335A001

Adapter, for 4" SCH40 PVC pipe

1

10

24335A000

Adapter, for 2" SCH40 PVC pipe

or conduit

2

11

13653-004-1

Flexible Discharge Pipe

1

12

11841-010-1

Discharge valve, single union

1

Not 

Shown

27682A001

Control Panel, Positive Displacement 

Pump

1

27682A000

Control Panel, Centrifugal Pump

1

8

7

12

11

1

2

4

5

9

6

10

10

Summary of Contents for Hydromatic

Page 1: ...ovide this manual to the owner of the equip ment or to the responsible party who maintains the system COMPLETE GRINDER PACKAGE SYSTEM TH PRO SYSTEM INSTALLATION AND SERVICE MANUAL Item E 03 515 Part 5625 515 1 2012 Pentair Pump Group Inc 11 05 12 ...

Page 2: ...ust be followed System must be properly grounded according to NEC Biohazard risk Once the wastewater source has been connected to system biohazard risk exists Installer s and or service personnel must use proper Personal Protective Equipment and follow handling procedures per OSHA 29 CFR 1910 1030 when handling equipment after wastewater source has been connected to the system Risk of fire or expl...

Page 3: ...drilled hole PIPE SIZE HOLE SAW DIAMETER 3 4 4 5 6 7 Contact the factory for availability of proper size hole saw if necessary 6 pipe size requires use of a fiberglass basin Failure to use a properly piloted hole saw may result in damage to basin which may result in structural failure or serious leaks Step 2 Lubricate inside lip of inlet grommet with pipe soap Clean outer end of influent pipe and ...

Page 4: ...ing live electrical connections Step 1 Obtain proper backfill material The backfill material provides as much as 90 of the basin s support under certain stress conditions The installer must be positive that correct bed and backfill materials are used per instructions as follows A Gravel clean and free flowing with particle size not less than 1 8 or more than 3 4 in diameter Use this description wh...

Page 5: ...g Grinding mechanism is extremely sharp Use caution when handling the grinder mechanism Risk of fire or explosion Do not smoke or use open flames in or around this system This system is not intended for use in hazardous locations per NFPA 70NationalElectricCode Consult factory for optional equipment rated for this use Unpacking Pump Remove pump from carton When unpacking unit check for concealed d...

Page 6: ...int at which the electrical conduit will enter the basin and using a 3 diameter properly maintained piloted hole saw drill a hole through the basin wall If using a fiberglass basin clean the edges of the hole and apply a sealant coating to the cut section to prevent fiberglass deterioration Insert the inlet grommet into the drilled hole Failure to use a properly piloted hole saw may result in dama...

Page 7: ... breaker Step 4 Start the pump by pushing the Push to run push button inside the control panel Step 5 Check the pump amperage with clamp on ammeter on black pump lead Readings higher than nameplate indicate clogged pump miswiring or improper voltage If basin is not being pumped down and amperage readings are considerably lower than nameplate then the pump is air locked 1 Cutters may be clogged Amp...

Page 8: ...ally suspend the Off float the pump should stop running If this procedure does not cause the pump to operate as described either replace the float s or replace the alternator relay if the system is duplex Circuit breaker trips when pump tries to start 1 Short circuit in pump motor 2 Water may have entered the motor housing through either worn out mechanical seals or O rings 3 Start component s fai...

Page 9: ...03 1 Stand for HPD200 Positive Displacement Pump 1 27078B005 Stand for HGRS200 Centrifugal Pump 1 3 12870 015 1 Junction Box NEMA 6 2 NPT 1 4 14595 320 1 Float control pump 20 cord 1 5 21813A322 Float control alarm 20 cord 1 6 22470B005 Float control bracket 1 7 23901D303 Basin 24 x 48 Fiberglass 1 23901D301 Basin 24 x 60 Fiberglass 1 23901D304 Basin 24 x 72 Fiberglass 1 23901D306 Basin 24 x 84 Fi...

Page 10: ...THIS PAGE INTENTIONALLY LEFT BLANK ...

Page 11: ...THIS PAGE INTENTIONALLY LEFT BLANK ...

Page 12: ...ting from failure to properly install operate or maintain the unit in accordance with the printed instructions provided b to failures resulting from abuse accident or negligence c to normal maintenance services and parts used in connection with such service d to units that are not installed in accordance with applicable local codes ordinances and good trade practices e if the unit is moved from it...

Reviews: