Pentair Hydromatic Installation And Service Manual Download Page 12

Warranty Rev. 12/13

STANDARD LIMITED WARRANTY

Pentair Hydromatic

®

 warrants its products against defects in material and workmanship for a period of 12 months 

from  the  date  of  shipment  from  Pentair  Hydromatic  or  18  months  from  the  manufacturing  date,  whichever  

occurs first – provided that such products are used in compliance with the requirements of the Pentair Hydromatic  

catalog  and  technical  manuals  for  use  in  pumping  raw  sewage,  municipal  wastewater  or  similar,  abrasive-free,  

noncorrosive liquids. 

During the warranty period and subject to the conditions set forth, Pentair Hydromatic, at its discretion, will repair 

or replace to the original user, the parts that prove defective in materials and workmanship. Pentair Hydromatic 

reserves the right to change or improve its products or any portions thereof without being obligated to provide such 

a change or improvement for prior sold and/or shipped units.

Start-up reports and electrical schematics may be required to support warranty claims. Submit at the time of start up 

through  the  Pentair  Hydromatic  website:  http://forms.pentairliterature.com/startupform/startupform.asp?type=h.  

Warranty is effective only if Pentair Hydromatic authorized control panels are used. All seal fail and heat sensing 

devices must be hooked up, functional and monitored or this warranty will be void. Pentair Hydromatic will cover 

only the lower seal and labor thereof for all dual seal pumps. Under no circumstance will Pentair Hydromatic be 

responsible  for  the  cost  of  field  labor,  travel  expenses,  rented  equipment,  removal/reinstallation  costs  or  freight 

expenses to and from the factory or an authorized Pentair Hydromatic service facility.
This limited warranty will not apply: (a) to defects or malfunctions resulting from failure to properly install, operate or 

maintain the unit in accordance with the printed instructions provided; (b) to failures resulting from abuse, accident 

or negligence; (c) to normal maintenance services and parts used in connection with such service; (d) to units that 

are not installed in accordance with applicable local codes, ordinances and good trade practices; (e) if the unit is 

moved from its original installation location; (f) if unit is used for purposes other than for what it is designed and 

manufactured;  (g)  to  any  unit  that  has  been  repaired  or  altered  by  anyone  other  than  Pentair  Hydromatic  or  an 

authorized Pentair Hydromatic service provider; (h) to any unit that has been repaired using non factory specified/

OEM parts.

Warranty  Exclusions:  PENTAIR  HYDROMATIC  MAKES  NO  EXPRESS  OR  IMPLIED  WARRANTIES  THAT  EXTEND 

BEYOND  THE  DESCRIPTION  ON  THE  FACE  HEREOF.  PENTAIR  HYDROMATIC  SPECIFICALLY  DISCLAIMS  THE 

IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR PURPOSE.

Liability  Limitation:  IN  NO  EVENT  SHALL  PENTAIR  HYDROMATIC  BE  LIABLE  OR  RESPONSIBLE  FOR  

CONSEQUENTIAL,  INCIDENTAL  OR  SPECIAL  DAMAGES  RESULTING  FROM  OR  RELATED  IN  ANY  MANNER  TO  

ANY  PENTAIR  HYDROMATIC  PRODUCT  OR  PARTS  THEREOF.  PERSONAL  INJURY  AND/OR  PROPERTY  DAMAGE  

MAY  RESULT  FROM  IMPROPER  INSTALLATION.  PENTAIR  HYDROMATIC  DISCLAIMS  ALL  LIABILITY,  INCLUDING 

LIABILITY  UNDER  THIS  WARRANTY,  FOR  IMPROPER  INSTALLATION.  PENTAIR  HYDROMATIC  RECOMMENDS 

INSTALLATION BY PROFESSIONALS.

Some states do not permit some or all of the above warranty limitations or the exclusion or limitation of incidental or 

consequential damages and therefore such limitations may not apply to you. No warranties or representations at any 

time made by any representatives of Pentair Hydromatic shall vary or expand the provision hereof.

1101 MYERS PARKWAY 

490 PINEBUSH ROAD, UNIT 4

ASHLAND, OHIO 44805 

CAMBRIDGE, ONTARIO, CANADA N1T 0A5

PH: 855-274-8947 

PH: 800-363-7867

WWW.HYDROMATIC.COM

Summary of Contents for Hydromatic

Page 1: ...ovide this manual to the owner of the equip ment or to the responsible party who maintains the system COMPLETE GRINDER PACKAGE SYSTEM TH PRO SYSTEM INSTALLATION AND SERVICE MANUAL Item E 03 515 Part 5625 515 1 2012 Pentair Pump Group Inc 11 05 12 ...

Page 2: ...ust be followed System must be properly grounded according to NEC Biohazard risk Once the wastewater source has been connected to system biohazard risk exists Installer s and or service personnel must use proper Personal Protective Equipment and follow handling procedures per OSHA 29 CFR 1910 1030 when handling equipment after wastewater source has been connected to the system Risk of fire or expl...

Page 3: ...drilled hole PIPE SIZE HOLE SAW DIAMETER 3 4 4 5 6 7 Contact the factory for availability of proper size hole saw if necessary 6 pipe size requires use of a fiberglass basin Failure to use a properly piloted hole saw may result in damage to basin which may result in structural failure or serious leaks Step 2 Lubricate inside lip of inlet grommet with pipe soap Clean outer end of influent pipe and ...

Page 4: ...ing live electrical connections Step 1 Obtain proper backfill material The backfill material provides as much as 90 of the basin s support under certain stress conditions The installer must be positive that correct bed and backfill materials are used per instructions as follows A Gravel clean and free flowing with particle size not less than 1 8 or more than 3 4 in diameter Use this description wh...

Page 5: ...g Grinding mechanism is extremely sharp Use caution when handling the grinder mechanism Risk of fire or explosion Do not smoke or use open flames in or around this system This system is not intended for use in hazardous locations per NFPA 70NationalElectricCode Consult factory for optional equipment rated for this use Unpacking Pump Remove pump from carton When unpacking unit check for concealed d...

Page 6: ...int at which the electrical conduit will enter the basin and using a 3 diameter properly maintained piloted hole saw drill a hole through the basin wall If using a fiberglass basin clean the edges of the hole and apply a sealant coating to the cut section to prevent fiberglass deterioration Insert the inlet grommet into the drilled hole Failure to use a properly piloted hole saw may result in dama...

Page 7: ... breaker Step 4 Start the pump by pushing the Push to run push button inside the control panel Step 5 Check the pump amperage with clamp on ammeter on black pump lead Readings higher than nameplate indicate clogged pump miswiring or improper voltage If basin is not being pumped down and amperage readings are considerably lower than nameplate then the pump is air locked 1 Cutters may be clogged Amp...

Page 8: ...ally suspend the Off float the pump should stop running If this procedure does not cause the pump to operate as described either replace the float s or replace the alternator relay if the system is duplex Circuit breaker trips when pump tries to start 1 Short circuit in pump motor 2 Water may have entered the motor housing through either worn out mechanical seals or O rings 3 Start component s fai...

Page 9: ...03 1 Stand for HPD200 Positive Displacement Pump 1 27078B005 Stand for HGRS200 Centrifugal Pump 1 3 12870 015 1 Junction Box NEMA 6 2 NPT 1 4 14595 320 1 Float control pump 20 cord 1 5 21813A322 Float control alarm 20 cord 1 6 22470B005 Float control bracket 1 7 23901D303 Basin 24 x 48 Fiberglass 1 23901D301 Basin 24 x 60 Fiberglass 1 23901D304 Basin 24 x 72 Fiberglass 1 23901D306 Basin 24 x 84 Fi...

Page 10: ...THIS PAGE INTENTIONALLY LEFT BLANK ...

Page 11: ...THIS PAGE INTENTIONALLY LEFT BLANK ...

Page 12: ...ting from failure to properly install operate or maintain the unit in accordance with the printed instructions provided b to failures resulting from abuse accident or negligence c to normal maintenance services and parts used in connection with such service d to units that are not installed in accordance with applicable local codes ordinances and good trade practices e if the unit is moved from it...