TROUBLE-SHOOTING
Your Control System is designed to provide years of trouble-free pool and spa enjoyment. However, if at any time your
System should behave erratically, consult the following Check List, which should help to alleviate any problems caused
by operator error. If you are still unable to solve your particular symptom, refer the situation to a qualified Pool Service
Company.
GENERAL
1. Check all circuit breakers at electrical sub-panel.
2. At the LX-100 RF Power/Load Center, ensure that all the
Service Switches
are in the “AUTO” position.
NOTHING OPERATES
1. Check 3-amp circuit breaker which is located above
FILTER PUMP Time Clock
in LX-100 RF Power/
Load Center. Tripped circuit breaker is indicated by a white tab. Push to reset.
2. If circuit breaker continues to trip, refer to a qualified Service Company.
FILTER PUMP DOES NOT OPERATE
1. At the LX-100 RF Power/Load Center, check that the
FILTER PUMP Time Clock
is programmed on.
2. Turn the
FILTER Service Switch
to the “ON” position. If the pump still does not operate, consult a
qualified Service Company.
FILTER PUMP DOES NOT TURN OFF
1. At the LX-100 RF Power/Load Center, check that the
FILTER Service Switch
is not in the “ON”
position.
2. Check that the
PUMP DELAY Status Light
is not on, indicating that the System is running its 4-minute
cool down cycle.
3. Check that the
POOL CLEANER Time Clock
is not programmed on, automatically forcing the filter pump on.
4. Turn the
FILTER Service Switch
to the “OFF” position. If the pump continues to run, consult a
qualified Service Company.
POOL CLEANER DOES NOT OPERATE
1. At the LX-100 RF Power/Load Center, check that the
POOL CLEANER Time Clock
is programmed on.
2. Make sure that
Push-button SPA
is not turned on by the Hand-held Remote.
3. Pool cleaner pump may require servicing.
HEATER DOES NOT OPERATE
1. Make sure that filter pump is running.
2. Check heater thermostat setting and pilot light (if applicable).
3. Check filter pressure. If filter is clogged, the heater may not be getting sufficient water flow.
4. Heater may require servicing.
SPA WATER LEVEL DROPS
1. At the LX-100 RF Power/Load Center, check that the
SPA Service Switch
is in the “AUTO” position.
2. Check that Motorized Valves rotate in both directions by adjusting toggle switch on the
rear of each Valve Actuators. Remember to return switches to their original position after testing.
3. A “check valve” in the system may be leaking. Refer to a qualified Service Company.