![background image](http://html.mh-extra.com/html/pentair/compool-lx-100ez/compool-lx-100ez_installation-and-owners-manual_1524364016.webp)
P/N 520050
16
Rev. F 3-26-04
POOL CLEANER
For systems which incorporate a booster pump pool cleaner, it is possible to add a mechanical time clock for
programming the daily cleaning cycles.
Install
24-Hour Time Clock
(
model TMR-LX
) into LX-100 RF Power/Load Center faceplate at the
POOL CLEANER
location, and plug into top of circuit board at
CLNR TIMER socket
, in accordance with instructions provided.
Install a
20-Amp Relay Kit
(
model RLY-LX
) at the LX-100 RF Power/Load Center in accordance with instructions
provided, and plug into circuit board at
CLNR relay socket
.
AUXILIARY VALVE
It is possible to add a
Valve Actuator
(
P/N 263045
) to the system to motorize a two-port or three-port valve for a
custom hydraulic feature (such as a pool cleaner, fountain, waterfall, etc.). The Valve Actuator can be activated from
either the pool cleaner or auxiliary 3 circuit.
Remove knob, handle and four screws from cap of valve to be motorized, and use the four mounting screws provided
to mount Valve Actuator to valve. Run cable to low-voltage compartment of LX-100 RF Power/Load Center, and plug
into circuit board at
AUX VLV Valve Socket
.
Identify the 2-position
AUX VLV Program Switch
, which is located at bottom right of LX-100 RF Power/Load Center
circuit board, and use the corner of a small screwdriver or other blunt instrument to adjust the Switch accordingly:
1. To activate valve from the pool cleaner circuit, turn
Switch #1
"ON" and
Switch #2
"OFF".
2. To activate valve from the auxiliary 3 circuit, turn
Switch #1
"OFF" and
Switch #2
"ON".