9.3.3 set torque reference
The set torque profile reference routine
allows to transfer the last torque profile to the
reference profile registers� The old reference
data are lost and the new ones are used as a
new reference torque profile�
• Move the local selector to OFF and then
simultaneously press OPEN and STOP�
Select the language and enter the password
according to the instructions (see “Entering
the set-up mode”)� When the message
displayed is “SET-UP MODE OK?” press YES.
Press NO to scroll the list of available menus
and then press yES to select maintenance
menu�
• Press NO to scroll the list of available
routines and then press yES to select Set
torque reference�
• Press YES to update the torque reference
data�
9.3.4 set curve reference
The “set curve reference” routine allows to
select 1 off 100 opening and closing torque
curves in the memory of the ICON 2000 and to
transfer them to the torque curve reference
registers� The old reference data are lost and
the new ones will be the new torque curves
reference (see VIEW mode, Maintenance,
Torque curve, paragraph 10�4�3)�
configuration procedure
• Move the local selector to OFF and then
simultaneously press OPEN and STOP� Select
the language and then enter the password
according to the instructions (see “Entering
the set-up mode”)� When the message
displayed is “SET-UP MODE OK?” press YES.
Press NO to scroll the list of available menus
and then press yES to select maintenance
menu�
• Press NO to scroll the list of available
routines and then press yES to select Set
curve reference�
• Press NO to scroll the list and then press YES
to select the desired curves (in opening and
closing)�
• Press YES to update the torque curve
reference�
9.3.5 clear recent data log
The clear recent data log routine allows to
clear the counters of the recent operation log�
This command does not affect the content of
the “general operation log”�
The date of the “clear recent data log”
is memorized and can be viewed in the
maintenance date routine of the view menu�
9.3 Maintenance
A large amount of data is stored in the actuator
memory and is available for future analysis
or to assist the operator in the maintenance
program� The maintenance menu also includes
the set password routine and the possibility to
modify or start the maintenance functions�
The following data are available:
- set password
- clear alarm log
- set torque reference
- set curve reference
- clear recent data log
- set maintenance date
- set data logger
9.3.1 set password
The actuator is supplied by Biffi with a default
password (“0 0 0 0”)� By the above routine
the end user can enter a different password
consisting of 4 alphanumeric characters� After
entering the new password, the old one ceases
to be valid� Therefore it is mandatory “NOT TO
fORGET THE PASSWORD” after the default
one has been modified� forgetting the new
password makes it impossible to enter the
set-up menu and to configure the actuator�
configuration procedure
• Move the local selector to OFF and then
simultaneously press OPEN and STOP�
Select the language and enter the password
according to the instructions (see “Entering
the set-up mode”)� When the message
displayed is “SET-UP MODE OK?” press YES.
Press NO to scroll the list of available menus
and then press yES to select Maintenance
menu�
• Press NO to scroll the list of available
routines and then press yES to select Set
password�
Press yES again to select Enter new
password�
• Enter the new password one digit at a time.
Press yES if the digit is correct, press NO
to scroll the list of available characters and
then press yES to select� Enter 4 digits� When
the display shows the message Password
changed the old password is no longer valid�
9.3.2 clear alarm log
clear procedure
• Move the local selector to OFF and then
simultaneously press OPEN and STOP�
Select the language and enter the password
according to the instructions (see “Entering
the set-up mode”)� When the message
displayed is “SET-UP MODE OK?” press YES.
Press NO to scroll the list of available menus
and then press yES to select the Maintenance
menu�
• Press NO to scroll the list of available
routines and then press yES to select clear
alarm log�
• Press YES to clear alarm log.
clearing procedure
• Move the local selector to OFF and then
simultaneously press OPEN and STOP�
Select the language and enter the password
according to the instructions (see “Entering
the set-up mode”)� When the message
displayed is “SET-UP MODE OK?” press YES.
Press NO to scroll the list of available menus
and press yES to select the maintenance
menu�
• Press NO to scroll the list of available
routines and then press yES to select clear
recent data log�
• Press YES.
• Press YES to clear or press NO to exit.