29
Biffi
ICON 2000
InstructIon and operatIng manual
set-up procedure
• Engage the manual override and move the
valve to the mid-travel position�
• Move the local selector to OFF and then
simultaneously press OPEN and STOP� Select
the language and then enter the password
according to the instructions (see “Entering
the set-up mode”)� When the message
displayed is “SET-UP MODE OK?” press
yES� Press yES to select the actuator set-up
menu, and then press yES again to start with
the stroke limits routine�
• Press YES if the closing torque limit is correct
or NO to scroll the list of available values�
When the value is correct, press yES�
• Press YES if the opening torque limit is
correct or NO to scroll the list of available
values� When the value is correct press yES�
• Press YES if the rotation to close is correct
(CW or CCW), or NO to change�
When the value is correct press yES�
• Press YES to set the close limit, or NO and
then yES to set the open limit�
close limit type
Press yES if the close limit type is correct
(torque or position), press NO to change it�
Press yES when the type is correct�
close limit by position
• Move the local selector to LOCAL. The local
controls can be used�
• Move the valve to closed position (by CLOSE
control or by handwheel)�
• Move the local selector to OFF.
• Press YES to confirm.
• Press YES to continue with the open limit
setting, or press NO and again NO to repeat
the close limit setting procedure� Press NO
and then yES to exit from the stroke limits
routine�
close limit by torque
• Move the local selector to LOCAL. The local
controls can be used�
• Press the CLOSE control. The actuator moves
in closing direction and when the configured
torque value is reached the motor is stopped
and the new position limit is memorized�
• Move the local selector to OFF.
• Press YES to confirm.
• Press YES to continue with the close limit
setting, or press NO and again NO to repeat
the close limit setting procedure� Press NO
and then yES to exit from the stroke limits
routine�
open limit type
• Press YES if the open limit type is correct
(torque or position), press NO to change it�
Press yES to confirm�
open limit by position
• Move the local selector to LOCAL. The local
controls become active�
• Move the valve to open position (by OPEN
control or by handwheel)�
• Move the local selector to OFF.
• Press YES to confirm.
• Press YES to exit, or press NO and then YES
to repeat the close limit setting procedure�
9� SET-uP ROuTINES
9.1 actuator set-up
9.1.1 set stroke limits
This routine allows the actuator to be
configured according to the type of valve it is
mounted on�
The following parameters will be set:
- Opening and closing torque limits: from 40%
to 100% of the nominal torque. The nominal
torque corresponding to 100% is set in-house
and is stated in the name plate menu for
reference�
- Close direction: clockwise (CW) or
counter-clockwise (CCW)� Most valves require
clockwise rotation of the stem when viewed
from the handwheel� Engage the manual
override and check if the valve closes with
clockwise or counter-clockwise rotation of
the handwheel�
- Close and open limits type: by position or by
torque� use the table below to choose�
Valve type
close limit
open limit
Gate (solid, flexible and split wedge), globe, metal seated
butterfly valves
Torque
Position
Ball, gate (parallel slide), plug valves, rubber seated
butterfly valves
Position
Position
Linear valves with back-seating on stem
Torque or position
Torque
open limit by torque
• Move the local selector to LOCAL. The local
controls become active�
• Press the OPEN control. The actuator moves
in opening direction and when the configured
torque value is reached the motor is stopped
and the new position limit is memorized�
• Move the local selector to OFF.
• Press YES to confirm.
• Press YES to exit or press NO and then YES to
repeat the close limit setting procedure�
If parameter “direction to close” is changed,
both limits (open and close) must be set�
set-up procedure
• Move the local selector to OFF and then
simultaneously press OPEN and STOP� Select
the language and then enter the password
according to the instructions (see “Entering
the set-up mode”)� When the message
displayed is “SET-UP MODE OK?” press
yES� Press yES to select the actuator set-up
menu, press NO and then press yES to select
the torque set-up routine�
• Press YES if the opening torque limit is
correct, press NO to scroll the list of available
values� Press yES when the value is correct�
• Press YES if the closing torque limit is
correct, press NO to scroll the list of available
values� Press yES when the value is correct�
Before leaving the stroke limits routine the
microprocessor calculates the new value of
the position resolution� If the stroke turns
are less than 2�7, the message “error re-try”
appears and the stroke limits procedure must
be repeated�
9.1.2 torque set-up
The output torque limits to close or to open
may be configured between 40% and 100%
of the nominal torque stated on the actuator
nameplate�