1.3 applicaBle standards and reGulations
1.4 terMs and conditions
Biffi guarantees each single product to be free
from defects and to conform to current goods
specifications� The warranty period is one year
from the date of installation by the first user,
or eighteen months from the date of shipment
to the first user, whichever occurs first� No
warranty is given for products or components
manufactured by third-party companies, or
for goods which have been subject to misuse,
improper installation, corrosion, or which have
been modified or repaired by unauthorized
personnel� Repair work due to improper use
will be charged at standard rates�
Terminal box
Electric motor
Local interface
Engagement lever
Internal sensor
Internal gears
Handwheel
equipMent protection leVel (epl) en 60079-14
explosive atmosphere
zone
epl
Gas
0
Ga
Gas
1
Ga or Gb
Gas
2
Ga or Gb or Gc
Dust
20
Da
Dust
21
Da or Db
Dust
22
Da or Db or Dc
hazardous zone
zone
categories according to 94/9/ec directive
Gas, mist or vapors
0
1G
Gas, mists or vapors
1
2G or 1G
Gas, mists or vapors
2
3G or 2G or 1G
Dust
20
1D
Dust
21
2D or 1D
Dust
22
3D or 2D or 1D
EN ISO 12100-1
Safety of machinery - Basic concepts, general principles for design�
Part 1-Basic terminology, methodology
EN ISO 12100-2
Safety of machinery - Basic concepts, general principles for design�
Part 2-Technical principles and specification
EN 60204-1
Safety of machinery - Electrical equipment of industrial machines
2006/42/EC
Machinery Directive
2006/95/EC
Low Voltage Directive
2004/108/EC
EMC Directive
94/9/EC
ATEX Directive