CAUTION

 

 

DO NOT tap on fittings as 

this could damage the ports.

 

 

 

 

Opening  The Vessel

 

 

 

 

 

WARNING

 

 

Relieve pressure from vessel 

before beginning this procedure.

 

 

Contamination  Removal

 

 

Metal oxidation products and mineral deposits can 
interfere with vessel disassembly. Remove all 
foreign matter from both ends of vessels as follows:

 

 

1.   Remove contaminants using a small wire-brush 

or suitable abrasive (such as medium-grade 
ScotchBrite

TM

)

 

Remove the Retaining  Ring from the groove

 

1.   Lift the tabbed  end of the retaining  ring up and out 

of  the  stainless steel  groove in  the  shell and  then 
away from the head so that it rests in the end margin 
of  the  vessel. This  is  best  accomplished  by  using 
CodeLine

®  

Removal Tool, part number 50303, which 

is  available from  your  supplier. This  can  also  be 
accomplished using a screwdriver and a pair of pliers 
if the tool is not readily available.

 

 

With  the  removal  tool  the  retaining  ring  can  be 
lifted  upward  by  simply  rotating  the  tool 
counterclockwise  after  inserting  it  over  the  tab  on 
the retaining ring (Use the smaller hole). Hold the 
tool flat against the end margin and parallel to the 
vessel bore. It is then possible to pull the end of the 
retaining ring straight out. The retaining ring may 
snap  back  into  the  groove  if  this  alignment  is  not 
closely adhered  to.  If  the retaining ring is  difficult 
to remove, try soaking with a release agent such as

 

LPS

TM

 

or   WD4

0TM

,   being   careful   to   avoid   any

 

contamination of a membrane element.

 

 

 

 

 

Cleaning inside the vessel

 

 

2.   Flush away loosened deposits with clean water.

 

 

Removing  the Head

 

The head assembly is shown in figure 1, pg 2.

 

 

Remove head as follows:

 

 

Disconnect  Permeate Piping

 

1.   Disconnect permeate piping as required at nearest 

convenient joint, being careful not to place undue 
stress on the threaded connections in the plastic 
permeate port.

 

 

Retaining Ring Removal Tool

 

 

 
 

When using screwdriver and pliers, pry the tabbed 
end  of  the  retaining  ring  out  of  the  stainless  steel 
groove with the tip of the screwdriver. Once the end 
of the retaining ring is clear of the groove, grab the 
tab with the pliers and pull towards the end of the 
vessel until the end of the ring is resting in the end 
margin of the shell.

 

 

Distributed by Applied Membranes, Inc. | www.appliedmembranes.com |  (760) 727-3711 |  USA

Summary of Contents for 40E100 RO

Page 1: ...may result in catastrophic failure pressurize vessel until after visually inspecting to ensure that the spiral retaining ring is correctly installed tolerate leaks or allow end closures to be routinel...

Page 2: ...nternally wound in place Shell exterior coated with white high gloss polyurethane paint Head 2 2 47471 Bearing Plate 6061 T6 hard anodiz ed Alum Alloy 3 2 50481 Seal Plate PVC Thermoplastic gray 120 F...

Page 3: ...ng ring Use the smaller hole Hold the tool flat against the end margin and parallel to the vessel bore It is then possible to pull the end of the retaining ring straight out The retaining ring may sna...

Page 4: ...3 Once the retaining ring has been removed examine the area for burrs or dings which could damage the head or membrane If necessary use ScotchBriteTM or 600 grade sandpaper to smooth the area Removin...

Page 5: ...nd upstream end is the end plumbed most directly to the pump 2 Push element s out of vessel from the upstream end 3 For multi element vessels remove the intercon nectors and retain for reinstallation...

Page 6: ...ons to the vessel and all around the vessel itself If any leaks occur release pressure from the vessel and tighten the fittings as necessary Then pressurize vessel and check for leaks again 8 Insert e...

Page 7: ...Plug Seal 2 Remove circlip from its groove in the Permeate port Take care not to scratch the hard anodized surface of the bearing plate Separate the Sealing plate and the Bearing plate 5 Push Feed Co...

Page 8: ...Use only head components in as new condition Use new O rings each time the head is assembled 2 Cover O rings with a this even layer of Parker Super O LubeTM silicon lubricant or the lubricant recomm e...

Page 9: ...to the machined end of the Feed Concentrate Port so that the two pairs of holes line up 7 Assemble the Permeate Port through the center hole in the Sealing Plate align the Permeate port pin with the S...

Page 10: ...etal parts using a wire brush 2 Scrub the entire surface with medium grade Scotch BriteTM until all contaminants are removed 3 Rinse parts clean with fresh water and dry 4 Inspect all parts for servic...

Reviews: