Refurbishing Parts (Contd...)

 

 

 

 

Refurbishing Shell

 

1.   Using a fine wire brush, remove any large deposits from

 

Retaining Ring groove in the vessel.

 

2.   Using a medium or finer grade of ScotchBrite

TM  

and mild

 

soap solution, clean the inside of the vessel at least 4 
inches in from each end.

 

3.   Use clean water to rinse away all loosened deposits 

and soap residue.

 

4.   Examine inside of the vessel for scratches, gouges or 

other imperfections that could prevent proper 
sealing. If such areas exist and leaks are observed 
when the vessel is placed back in service, the shell 
may need to be replaced.

 

Seals should be replaced necessarily, each time the 
vessels are serviced. Any parts that need to be 
replaced are available from your supplier or from 
Pentair Water.

 

 

Refurbishing Other Parts

 

1.   Remove any large deposits from metal parts using 

a wire brush.

 

2.   Scrub the entire surface with medium grade Scotch-

 

Brite

TM  

until all contaminants are removed.

 

3.   Rinse parts clean with fresh water and dry.

 

4.   Inspect all parts for serviceability as specified above.

 

Remaking  Pipe Connections  to End

 

Plug

 

1.   Use a wire brush to remove all foreign matter from 

threads on pipe fittings.

 

2.   Scrub the entire surface with medium grade Scotch-

 

Brite

TM  

until all contaminants are removed.

 

3.   Rinse parts clean with fresh water and dry.

 

4.   Inspect all parts for serviceability as specified above.

 

 

 

NOTE

 

 

If the head has to be reoriented  to attain 

suitable  port positions, head will have to

 

be removed and reinstalled  as described in

 

Head Assembly section.

 

 

Part Replacement

 

Replace all parts that cannot be restored to as-new condition.

 

Replace any parts showing signs of structural damage or 
corrosion

 

 

 

CAUTION

 

 

Use  of components  that  are damaged by 

corrosion can result in catastrophic 

failure.

 

 

 

Distributed by Applied Membranes, Inc. | www.appliedmembranes.com |  (760) 727-3711 |  USA

Summary of Contents for 40E100 RO

Page 1: ...may result in catastrophic failure pressurize vessel until after visually inspecting to ensure that the spiral retaining ring is correctly installed tolerate leaks or allow end closures to be routinel...

Page 2: ...nternally wound in place Shell exterior coated with white high gloss polyurethane paint Head 2 2 47471 Bearing Plate 6061 T6 hard anodiz ed Alum Alloy 3 2 50481 Seal Plate PVC Thermoplastic gray 120 F...

Page 3: ...ng ring Use the smaller hole Hold the tool flat against the end margin and parallel to the vessel bore It is then possible to pull the end of the retaining ring straight out The retaining ring may sna...

Page 4: ...3 Once the retaining ring has been removed examine the area for burrs or dings which could damage the head or membrane If necessary use ScotchBriteTM or 600 grade sandpaper to smooth the area Removin...

Page 5: ...nd upstream end is the end plumbed most directly to the pump 2 Push element s out of vessel from the upstream end 3 For multi element vessels remove the intercon nectors and retain for reinstallation...

Page 6: ...ons to the vessel and all around the vessel itself If any leaks occur release pressure from the vessel and tighten the fittings as necessary Then pressurize vessel and check for leaks again 8 Insert e...

Page 7: ...Plug Seal 2 Remove circlip from its groove in the Permeate port Take care not to scratch the hard anodized surface of the bearing plate Separate the Sealing plate and the Bearing plate 5 Push Feed Co...

Page 8: ...Use only head components in as new condition Use new O rings each time the head is assembled 2 Cover O rings with a this even layer of Parker Super O LubeTM silicon lubricant or the lubricant recomm e...

Page 9: ...to the machined end of the Feed Concentrate Port so that the two pairs of holes line up 7 Assemble the Permeate Port through the center hole in the Sealing Plate align the Permeate port pin with the S...

Page 10: ...etal parts using a wire brush 2 Scrub the entire surface with medium grade Scotch BriteTM until all contaminants are removed 3 Rinse parts clean with fresh water and dry 4 Inspect all parts for servic...

Reviews: