CAUTION

 

 

If vessel is to be pressurized  above 125 psi 

without elements installed, the central 

permeate port  should be plugged from the 

inside. Solid adapters are available for this 

purpose.

 

 

CAUTION

 

 

When lubricating  the vessel chamfer, 

wear protective gloves or finger cots to 

prevent cuts or penetration of 

fiberglass.

 

 

 

 

Replacing  Elements

 

 

 

 

The following procedures are provided for information 
only. Elements should be installed in accordance with 
the element manufacturer’s recommendations. Where 
conflicts exist, contact the element manufacturer or 
Pentair Water  for clarification.

 

 

To replace elements, proceed as follows:

 

 

Removing  Elements

 

4.    Install  adapter  if  required  into  one  end  plug.  At 

downstream    end   of   vessel,   orient   end   plug 
ports  into  desired  position  and  push  plug  fully 
into   vessel.   A   sharp,   forceful   thrust   may   be 
needed  to  enter  plug  seal  into  the  vessel  bore.

 

1.   Remove heads from both ends of the vessels as 

described in Opening the Vessel.

 

 

 

NOTE

 

 

Always  remove and install  element in 

the direction  of feed flow. The feed end 

(upstream end) is the end plumbed 

most directly to the pump.

 

 

2.   Push element(s) out of vessel from the upstream 

end.

 

3.   For multi-element vessels, remove the intercon- 

nectors and retain for reinstallation.

 

 

 

 

Installation  of the End Plug  Assembly 

into the vessel

 

 

Inserting  Elements

 

1.   Ensure that heads are available in clean, as-new 

condition before proceeding. (If in doubt as to 
head condition see section on inspecting parts, 
page 10).

 

 

2.   Check that all required elements are ready for assem- 

bly, with no dings or other damage which could 
scratch the inside of the vessel.

 

 

3.   Check that the interior of the vessel is clean and free 

of burrs, sharp edges or other damage.

 

Remove any residual lubricant from the vessel bore 
and work a fresh, thin film of Parker-Super O-Lube

TM 

silicon lubricant into the lead-in chamfer and an area 
approximately ½ inch in from the chamfer

 

5.   Carefully   insert   retaining   ring   into  its  groove.

 

This  is  done  by  inserting   the  lead  end  of  the 
spiral  retaining  ring  (end  without  bent  tab)  into 
the   stainless  steel  retaining  ring  groove  located 
in  the  shell,  and  slowly  pushing  the  remaining 
turns  into  the  shell.

 

 

 

 

 

 

 

 

Inserting Retaining Ring into the groove

 

 

Distributed by Applied Membranes, Inc. | www.appliedmembranes.com |  (760) 727-3711 |  USA

Summary of Contents for 40E100 RO

Page 1: ...may result in catastrophic failure pressurize vessel until after visually inspecting to ensure that the spiral retaining ring is correctly installed tolerate leaks or allow end closures to be routinel...

Page 2: ...nternally wound in place Shell exterior coated with white high gloss polyurethane paint Head 2 2 47471 Bearing Plate 6061 T6 hard anodiz ed Alum Alloy 3 2 50481 Seal Plate PVC Thermoplastic gray 120 F...

Page 3: ...ng ring Use the smaller hole Hold the tool flat against the end margin and parallel to the vessel bore It is then possible to pull the end of the retaining ring straight out The retaining ring may sna...

Page 4: ...3 Once the retaining ring has been removed examine the area for burrs or dings which could damage the head or membrane If necessary use ScotchBriteTM or 600 grade sandpaper to smooth the area Removin...

Page 5: ...nd upstream end is the end plumbed most directly to the pump 2 Push element s out of vessel from the upstream end 3 For multi element vessels remove the intercon nectors and retain for reinstallation...

Page 6: ...ons to the vessel and all around the vessel itself If any leaks occur release pressure from the vessel and tighten the fittings as necessary Then pressurize vessel and check for leaks again 8 Insert e...

Page 7: ...Plug Seal 2 Remove circlip from its groove in the Permeate port Take care not to scratch the hard anodized surface of the bearing plate Separate the Sealing plate and the Bearing plate 5 Push Feed Co...

Page 8: ...Use only head components in as new condition Use new O rings each time the head is assembled 2 Cover O rings with a this even layer of Parker Super O LubeTM silicon lubricant or the lubricant recomm e...

Page 9: ...to the machined end of the Feed Concentrate Port so that the two pairs of holes line up 7 Assemble the Permeate Port through the center hole in the Sealing Plate align the Permeate port pin with the S...

Page 10: ...etal parts using a wire brush 2 Scrub the entire surface with medium grade Scotch BriteTM until all contaminants are removed 3 Rinse parts clean with fresh water and dry 4 Inspect all parts for servic...