![Pentair Pool Products PG2000 840240 Installation Manual Download Page 12](http://html1.mh-extra.com/html/pentair-pool-products/pg2000-840240/pg2000-840240_installation-manual_1525917012.webp)
P/N 840259
12
Rev. C 7-29-05
C. Pulling or feeding pre-cut cable.
1. For Standard Gunite lens housing and Fiberglass lens housing remove the spacer and spacer O-ring using
diagonal-cutters.
2. Remove the reminder tag from the cable.
3. If needed, push the fish tape through the conduit from the PG2000 side.
NOTE
In many cases, AmerGlow cable may be fed through conduit without the use of a fish tape.
4. Attach the cable to fish tape at the poolside with duct or electrical tape, cover the fibers completely with tape.
5. Reel up fish tape while second person pushes the cable from the pool side. If necessary, apply electrician’s lube
on the cable as it is fed through.
a. Keep the last foot of cable on the lens side as straight as possible.
b. Be careful not to damage the lens assembly.
6. Stop feeding the cable when one foot is left on the pool side.
a. Make sure the lens O-ring and spacer O-ring (if applicable) are in position and clean.
b. Clean the O-ring sealing surface on the inner flange of the lens housing.
7. Continue to pull the cable until the lens assembly is 1 in. away from the seated position.
CAUTION
DO NOT snug the lens into place by pulling on the cable! This may cause the cable to pull away from the lens, and will impair
performance of the Termination.
8. Place the lens retaining nut onto the lens and PUSH the lens into place.
9. Hand tighten the lens using the lens tightening tool, until the O-ring is seated.
a. For standard gunite and fiberglass lens housings (which do not use the spacer and spacer O-ring),
hand
tighten
¼ turn past the seated O-ring position.
b. For Invisible Gunite and Vinyl Liner housings (which use the spacer and spacer O-ring),
hand tighten
the
lens retaining nut ½ turn past the O-ring’s seated position.
D. Pulling or feeding bulk cable.
1. Push the fish tape through the conduit from the pool end. In many cases, AmerGlow cable may be fed through
conduit without the use of fish tape.
2. Attach the cable to the end of the fish tape using duct or electrical tape. Cover the fibers completely with tape.
Pull cable through conduit using electrician’s lube if needed.
3. Leave about one (1) ft. of cable extending past the lens housing, and about one (1) ft. above the PG2000
mounting surface. If desired, leave cable on spool and cut to exact length after lens is assembled.
SECTION VI.
AmerGlow Lens Assembly
A. What you’ll need:
√
Fiber Termination Kit, P/N 21005500. Contains: cable stripper, hot knife, spare blades, cutting shield, lens
tightening tool, and OptiFusion gel.
√
Cable Cutters
√
Wire snips
√
Channel locks
√
Crescent wrench
√
Electrical Tape