background image

Chap.1 – 

General information

Chap.2 – 

Limits of use

Chap.3 – 

Hydraulic Installation

Chap.4 – 

Priming of the group

Chap.5 – 

Electric connection

CONTENTS

Chap.6 – 

Starting up

Chap.7 – 

Varation of operational parameters

Chap.8 – 

Units whit periodic autotest

Chap.9 – 

Trouble shooting

17

GENERAL SAFETY WARNINGS

Warnings for the safety of users and objects.
Pay particular attention to the signs and their symbols

DANGER

Risk of electrical
discharge

.

DANGER

WARNING

The nonobservance of instructions may lead to risk of electrical
discharge.

The nonobservance of instructions may cause damage to people and/
or things.

The nonobservance of the instructions may lead to damage of the motor
pump.

CAUTION: before assembling, carefully read the contents of this manual. The nonobservance of the instructions
will result in the annulment of the warranty.

Chap.1 – General Information

Our pressurization groups must be installed in premises protected against bad weather and frost, well ventilated and
in a non dangerous atmosphere. Each of our groups is entirely tested in our establishments.
Upon delivery, check that the group has not suffered any damage during transportation; in this case, contact immediately
the retailer. In case of claims, contact immediately the retailer within eight days of purchase.

Chap.2 – Limits of use

Our pressurization groups are constructed for the raising clean water without solid suspended particles or abrasive
materials.

WARNING

The group is not suitable for pumping chemically aggressive or
inflammable liquids.

WARNING

Avoid any dry-operating of the motor pump.

MAXIMUM TEMPERATURE OF THE LIQUID PUMPED

40°C

MAXIMUM/MINIMUM AMBIENT TEMPERATURE

40°C

Chap.3 – Hydraulic installation

DANGER

Risk of electrical
discharge.

All the assembly operations must be carried out with group
disconnected from the power grid.

In the case where the pressurization group is fed by a tank, avoid any unpriming phenomena; we recommend to
control the following characteristic data:

- static level (initial level of the well)
- dynamic level (level reached during the group operation)
- flow rate

Fig.2 shows the assembly diagrams normally used.

GB

DANGER

L’utilisation de cet appareil n’est pas prévu par les personnes (y compris les enfants) avec des
capacités physiques, sensorielles ou mentales réduites, ou bien sans expérience et connaissance,
sauf en cas de supervision ou de formation par l’intermédiaire d’une personne responsable
garantissant la sécurité quant à l’utilisation de l’appareil.
Il faut surveiller les enfants afin qu’ils ne jouent pas avec cet appareil.

Summary of Contents for Nocchi Pressomat

Page 1: ...gs und Wartungsanleitung E Manual de uso y manutenci n NL Handleiding voor gebruik en onderhound PL Recyzny uzywaine i obslugi RUS Bycnherwbb gj ecnfyjdrt b Bycnherwbb gj ecnfyjdrt b Bycnherwbb gj ecn...

Page 2: ...i direktivene gjengitt nedenfor EU VAATIMUSTENMUKAISUUSVAKUUTUS Yhti Pentair International Sarl ilmoittaa omalla vastuullaan ett alla osoitetut tuotteet ovat oleellisten turvallisuus ja terveydensuoj...

Page 3: ...ely the retailer In case of claims contact immediately the retailer within eight days of purchase Chap 2 Limits of use Our pressurization groups are constructed for the raising clean water without sol...

Page 4: ...t pressure in the installation or with the tanks disassembled Chap 4 Priming of the group DANGER Risk of electrical discharge Always shut off the voltage before proceeding to any operation WARNING the...

Page 5: ...Once all the hydraulic and electric connections have been done for the hydraulic priming of the pumps and collectors proceed as follows close all the valves of the distribution system open all the va...

Page 6: ...to 0 OFF From then on the unit will automatically work according to the quantity of water withdrawn by its use Change of the working pressure setup Our units are set and tested during manufacture and...

Page 7: ...small collector by bringing the pressure to the level start pump that we want to assign to pressure switch n 1 tighten screw B of pressure switch n 1 to the point where its electric contact closes ON...

Page 8: ...ped WARNING The calibration values of the pressure switch must be between the minimum and maximum working pressure levels foreseen for the pump used in the unit and reported in the plate applied to th...

Page 9: ...NO Line n 1 COMPRESSOR With keys 16 or 17 it is possible to set the parameter YES or NO YES means that the unit has a pump and an air compressor operated by the same switchboard In this example NO Li...

Page 10: ...essage will appear ENTER TIMING PUMPSN 3s 060 Line n 1 Timing Noparameter Line n 2 PUMPS N 3 s With keys 16 or 17 it is possible to set the parameter to any value between 0 and 255 seconds This indica...

Page 11: ...ollowing message will be displayed In this case both the green led 2 and the red led 5 are lit BEFORETHEBUZZEREMITSTHE8th EIGHTH RING Press key 11 for a few seconds The following message will be displ...

Page 12: ...ted by the same switchboard In the example NO Line n 2 no message After choosing the parameter press key 18 the following message will appear ENTER DELAY FC S 40 ACTIVATION FC s X60 Line n 1 DELAY FC...

Page 13: ...pump will be stopped XXX seconds after having reached the maximum pressure set In the case of this example it is for 40 seconds After choosing the parameter press key 18 the following message will app...

Page 14: ...isplayed M A MANUALE FUNCTION BAR 5 3 The buzzer automatically sounds off and the red led 5 remains turned on Press key 18 for 2 seconds and the following message will be displayed LINEA MAN MAN ENTER...

Page 15: ...r 17 set the number in tens of minimum pressure values for the second pump normally 0 Confirm by pressing key 18 The cursor will change position depending on the number of units involved With keys 16...

Page 16: ...BARs normally 0 3 to 1 0 lower than the value assigned to pump 3 Line n 2 MIN0X XS With keys 16 or 17 set the number in tens of minimum pressure value of the fourth pump normally 0 Confirm by pressin...

Page 17: ...mechanic seal etc it is advisable to provide the machine with devices for the periodic starting of the pump and for the signaling of possible damages These additionally have the followings devices 1 w...

Page 18: ...ch on I ON Replace the disconnected fuses Press the AUT switch Restore the water level GB Theconnectingtubeofthepressure switches are obstructed The pressure switches cable is by passed The push selec...

Page 19: ...129 Fig 2 a...

Page 20: ...130 I Fig 2 b...

Page 21: ...131 Fig 3...

Page 22: ...132 Fig 5...

Page 23: ...133 Fig 4 Fig 6 Fig 7 Fig 8 Fig 9...

Page 24: ...134 Fig 10...

Page 25: ...s t correctement effectu s Si la panne est due des causes de force majeure ou d autres facteurs externes et incontr lables Si le produit est utilis avec des liquides abrasifs ou corrosifs ou diff rent...

Page 26: ...elni a k vetkez iratokat v s rl st igazol sz mla r szletes hibabejelent Niniejsze urz dzenie obj te jest gwarancj prawn zgodnie z przepisami i normami obowi zuj cymi w danym pa stwie w dniu zakupu pok...

Page 27: ...253P8800 PENTAIR INTERNATIONAL S a r l Avenue de Sevelin 18 1004 LAUSANNE Switzerland...