IntelliBrite
®
5g White Pool Light and White Spa Light Installation and User’s Guide
18
3.
Using a #3 Phillips head screwdriver, loosen the CLAMP SCREW and
remove uni-tension wire clamp from the face ring.
4.
Remove the face ring and wire clamp from the light housing and
set
aside for installation later.
5.
With the light assembly resting on its base, carefully pry off the gasket to
release the lens. Discard the gasket. A NEW LENS GASKET MUST BE
USED EACH TIME THE SPA LIGHT IS REASSEMBLED
6.
Disconnect the IntelliBrite Spa color light assembly cord from the junction
box.
Cut the cord near the back of the light assembly and discard the
light. See page 6 for replacement instructions for the new spa light.
Loosen the
Phillips screw
to remove wire
clamp from
face ring
Spa light fixture with lens, gasket
and face ring attached
Note: A 120 VAC to 12 VAC
external transformer is
required for the 12 VAC
model IntelliBrite Spa light.
See page 2 for more
information.
Note:
Note: The IntelliBrite Spa
Light fixture is a sealed light
assembly with no replaceable
circuit board assembly. Only the
lens, gasket and face ring can be
removed from the sealed light
assembly for replacement. See
page 23 for replacement kit part
numbers.
Lens
(keep
lens)
Spa light assembly
Face ring and uni-
tension wire clamp
Cut cable and discard
light assembly
Discard old
gasket
Phillips screw