5.
Place a cloth on the ground
to protect the lens. Turn the
light over so the lens is
resting on the cloth. Using a
¼" nut driver and a #3
Phillips screwdriver, remove
the nut uni-tension wire
clamp. Place the nut aside
for reinstallation.
6.
Remove the face ring
and wire clamp from the
light housing.
7.
With the light resting on
its base, carefully pry off
the gasket to remove the
lens. Set the lens aside
for installation later.
Discard the gasket.
Note: A NEW LENS
GASKET
(P/N 79101600) MUST
BE USED EACH TIME
THE LIGHT IS
REASSEMBLED.
See page 15 for
Replacement Kit part
numbers.
REPLACING THE INTELLIBRITE WHITE POOL LIGHT CIRCUIT BOARD
ASSEMBLY (IN AN EXISTING POOL) (Continued)
uni-tension
wire clamp:
Remove nut
and screw
Face ring
Lens
Note: Note the current position of the lens at the pilot screw (12 o’clock)
position, before removing it from the fixture. “W” on the lens indicates wide
angle, “N” indicates narrow angle. For more information, see page 13.
Gasket
8.
Using a ¼" nut driver, carefully remove the four retainer nuts from the light
assembly (see illustration on next page). Place the nuts aside for
reinstallation.
9.
Unplug the two connector plugs from the circuit board. Lift up the circuit
board and remove it from the light housing base.
10. Carefully lift off the old thermal strips from the base of the light housing
base and discard.