5
IntelliFlo
®
Pump Demo Kiosk Operation and Set-Up Instructions
IntelliFlo
®
Pump Demo Kiosk Operation and Set-Up Instructions
Discharge Foot Section
1. Install the lower end through the corresponding 2” Diameter opening in the top water tub by feeding the leg down
through the top lid openings.
2. Install the large white diffuser onto the bottom end of the pipe.
Suction Foot Section
1. Install the lower pipe end through the corresponding 1-1/2” diameter opening in the top of the water bucket by
feeding the leg down through the lid openings.
2. Install the small white diffuser onto the bottom end of the pipe. Do not glue the diffusers. The diffusers will need to
be removed if cleaning or replacing the water tub.
3. Slide the water tub, lid, and pipes into the open area on the left side of the kiosk cabinet with the 1 1/2” suction
pipe section facing toward the front.
Installing White PVC Piping (Inside Cabinet)
Flexible Coupling Connections
1. Install both ends of the coupling connections onto corresponding white PVC and gray PVC piping.
2. Align each pipe to be sure pipe ends are flush. Tighten with a 5/16” nut driver. (Do not over-tighten; clamps may
strip and possibly cause leaking).
3. Route the flow sensor connector through the divider wall, and plug into the DAQ-202 “Black Box”.
Pipe end flush
with inside edge
of flexible piping
Align pipe clamps
for easy access
to cabinet front
Water tub lid
with holes
Discharge pipe
section 2” diameter
Suction pipe section
1-1/2” diameter
White
Diffusers
Install with suction
pipe (1-1/2”)
section toward front
of cabinet as shown