Attention Installer: 

This manual contains important information about the installation, operation and safe use of this 

product. This information should be given to the owner and/or operator of this equipment. Additional copies of this manual 
are available at: 

http://www.thermal-solutions.com/customerdata/pentair/Kiosk%20Instructions

/

Before installing this product, read and follow all warning notices and instructions which are included. Failure to follow safety 
warnings and instructions can result in severe injury, death, or property damage. When installing and using this electrical 
equipment, basic safety precautions should always be followed, including the following:

READ AND FOLLOW ALL INSTRUCTIONS

SAVE THESE INSTRUCTIONS

Technical Support for IntelliFlo

® 

Operation

If you have questions about Pentair Water Pool and Spa 
(“Pentair”) IntelliFlo

®  

pump operation, please use the following 

contact information:

Sanford, North Carolina

 (8 A.M. to 5 P.M. ET)

Phone: (919) 566-8000
Fax: (919) 566-8920

Moorpark, California

 (8 A.M. to 5 P.M. PT)

Phone: (805) 553-5000 (Ext. 5591)
Fax: (805) 553-5515

Web site:

visit www.pentairpool.com or www.staritepool.com

Pump Demo Manual Rev. A2  2/29/12

© 2012 Pentair Water Pool and Spa, Inc. All rights reserved. 

1620 Hawkins Ave., Sanford, NC 27330 • (919) 566-8000
10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 553-5000

This document is subject to change without notice.

IntelliFlo

®

 and Pentair Water Pool and Spa

®

 are trademarks and/or registered trademarks of Pentair Water Pool and Spa, Inc. and/or its 

affi liated companies in the United States and/or other countries. Unless noted, names and brands of others that may be used in this 
document are not used to indicate an affi  liation or endorsement between the proprietors of these names and brands and Pentair Water 
Pool and Spa, Inc. Those names and brands may be the trademarks or registered trademarks of those parties or others.

Always disconnect power to the pump at the circuit breaker and disconnect the communication cable before 
servicing the pump. Failure to do so could result in death or serious injury to service people, users or others 
due to electric shock. Read all servicing instructions before working on the pump.
To reduce the risk of injury, service should only be performed by a qualifi ed service professional. 
To reduce the risk of injury, do not permit children to use this product. 

DO NOT open the strainer pot if pump fails to prime or if pump has been operating without water in the 
strainer pot. Pumps operated in these circumstances may experience a buildup of vapor pressure and 
may contain scalding hot water. Opening the pump may cause serious personal injury. In order to avoid 
the possibility of personal injury, make sure the suction and discharge valves are open and strainer pot 
temperature is cool to touch, then open with extreme caution

IMPORTANT! READ BEFORE TURNING ON THE PUMP

The pump can draw up to 3000 watts of power during priming and start up (typical 120V 20 Amp circuit is limited 
to 1800 watts maximum). Check to be sure the pump watt and power usage does not exceed the rated capacity of 
the electrical outlet. 
For continued, safe operation, 

set the pump’s maximum speed prior to operation. The pump should not run 

on a high speed for an extended length of time. 

Refer to the IntelliFlo

®

 installation and user’s guide for 

instructions on how to set the pump’s maximum speed. 

Summary of Contents for DAQ-202

Page 1: ...IntelliFlo Pump Demo Kiosk Operation and Set Up Instructions Pre Installed Live Pump Demo...

Page 2: ...nt is subject to change without notice IntelliFlo and Pentair Water Pool and Spa are trademarks and or registered trademarks of Pentair Water Pool and Spa Inc and or its affiliated companies in the Un...

Page 3: ...s Shipping Contents Quick Reference Guide Connection Diagram Cabinet Set Up Front Handle Installation Base Cabinet and Pump Module Assembly Connecting Pump to Power Supply Installing the Piping Gray P...

Page 4: ...ischarge Lo Pressure TDH pump suction LEGEND LO HI ON OFF FLOW PRESSURE Step Up Transformer 120V 240V Laptop 19 LCD Monitor Power Up Sequence 1 Main 120V Supply ON 2 Transformer ON 3 Black Box On 4 Mo...

Page 5: ...sembly includes IntelliFlo pump Threaded union adapters attached to pump Pump mounted on mounting board LCD monitor stand Power cord Front Handle Assembly Using a Philips head screw driver attach the...

Page 6: ...low Assembly into the clear pipe end of the assembly 3 Start by placing the tasselled end into the opening and continue by pushing into the pipe until the metal ring is flush out inside the gasket see...

Page 7: ...Slide the water tub lid and pipes into the open area on the left side of the kiosk cabinet with the 1 1 2 suction pipe section facing toward the front Installing White PVC Piping Inside Cabinet Flexi...

Page 8: ...EGEND LO HI ON OFF FLOW PRESSURE Step Up Transformer 120V 240V Laptop 19 LCD Monitor Power Up Sequence 1 Main 120V Supply ON 2 Transformer ON 3 Black Box On 4 Monitor ON 5 Laptop ON Critical Step Moni...

Page 9: ...ower cord may be routed through the 2 diameter opening located in the back wall of the cabinet 3 The transformer Power On switch should be facing the front of the cabinet Plug A C power strip into the...

Page 10: ...et on the upper right shelf Do not turn on the computer Follow the start up sequence on page 16 Setting up the Wireless Mouse 1 Be sure to plug in USB adapter for wireless mouse The adapter may be loc...

Page 11: ...pump board 3 Connect to the pump by pushing the quick release metal tabs on the connectors at the pump when installing the tube ends 4 RED end goes to the HIGH pressure connector discharge BLUE goes t...

Page 12: ...are found press the Stop Start button on the pump keypad tighten loose connections and resume start up 5 Turn the monitor ON Note Turn on monitor before turning on the computer 6 Turn the wireless mou...

Page 13: ...First uninstall the current version to be sure you have latest software update 1 Click the Start menu lower right corner of tool bar and click Control Panel 2 Select Programs and Features 3 Select Pen...

Page 14: ...the energy savings for a Standard vs IntelliFlo Variable Speed pump using the default values 4 To input your savings scenario click Click Here to Change Pool Description and follow the on screen instr...

Page 15: ...on the selected pool size 6 To exit this screen and return to the 3 Meters Screen right click on the upper left corner of the screen 7 From the 3 Meter Screen there is also an informational video on t...

Page 16: ...on set to 1440 x 900 resolution To switch between Calculator and pool size selection screen press Alt and Shift at the same time Demo kiosk shipments may include a flash drive with the latest software...

Reviews: