17-00001-C
Page | 19
Machine setup (continued)
If the machine is equipped with a Modular Autofeed System (MAS):
3. Air must be connected to the fitting on the black hose which extends down from the bottom of the
MAS. Connect an air line that is capable of delivering of clean, dry air.
For further instructions,
reference the Modular Auto Feeder Operation and Maintenance Manual Section of this manual.
Air Flow
Air Pressure
3 ft3/min - 85 l/min
90
psi/620 kPa 2-3 CFM
4. If the machine is not yet filled with oil, remove the sides of the machine. Fill the machine with AW
Exxon Humble Hydraulic H or equivalent premium hydraulic oil. Replace the sides when finished.
Fill the reservoir of the machine with the amount of
hydraulic oil listed below:
Machine
Gallons
Liters
824 Window Touch 4e
22
83
Right and left panels can be
removed to access Hydraulics.
Summary of Contents for Haeger 824 WindowTouch-4e
Page 1: ...17 00001 C Page 1 824 WindowTouch4e Operation Manual ...
Page 111: ...17 00001 C Page 111 155 Program Ends and returns to Main Screen ...
Page 136: ...17 00001 C Page 136 Parts List Main Assembly ...
Page 138: ...17 00001 C Page 138 Parts List MAS 350 Bowl Assembly ...
Page 141: ...17 00001 C Page 141 Parts List Quick Mount Assembly ...
Page 143: ...17 00001 C Page 143 Parts List Muti Shuttle 2 Assembly ...
Page 145: ...17 00001 C Page 145 Parts List HMI Arm Assembly ...
Page 147: ...17 00001 C Page 147 Parts List TIS Assembly ...
Page 153: ...17 00001 C Page 153 Parts List Hydraulic Cylinder Main Assembly ...
Page 155: ...17 00001 C Page 155 Parts List Electrical Cabinet High Low Voltage Assembly ...
Page 158: ...17 00001 C Page 158 Parts List Hydraulic Reservoir Assembly ...
Page 161: ...17 00001 C Page 161 Parts List Hydraulic Manifold Assembly ...