17-00001-C
Page | 49
Step 2: conductive mode test
Never attempt to test or
demonstrate this machine
’
s Safety
System by placing any portion of your hand or body
between the
Upper and Lower tools. Always use the test
procedure outlined in
Step 3
of this manual.
NEVER
Operate this Machine without the proper tooling installed. If
no material and fastener is used, you must use two flat anvils.
1.
Following the Upper and Lower Tool Installation instructions, install the 1 in. / 25 mm Flat Anvils in both
the Upper Tool
Holder and the Lower Tool Holder
.
2.
If you have just completed
Step 1:
“Safety
Switch Test Procedure
,”
a. The machine is
On
and the green light in the
On
Switch is still illuminated. If not, return to Step 1
and restart the machine by following Instructions 1 and 2.
b. The Conductive/Non-Conductive selection is in the
Conductive
display. If not, select the
Conductive
.
3. Set the machine to Setup mode by touching the circle next to the word Setup on the screen
4. Change the machine
’
s force to 3,000 lb (13KN) by touching the box next to Force, entering 3000
and touching the Enter
button. You can also use the +/- buttons.
5. Raise the Upper Tool Holder about 4 in./100 mm by depressing the Up Footswitch.
6. Keep your hands away from the tooling area.
a. Depress the
Down
Footswitch. The Upper Tool Holder should move down, the Anvils will
contact, the machine will apply the set force to the Lower Anvil and the Upper Tool Holder will
return to the Up position.
b. If this machine completes the above sequence correctly, go to
Instruction 8.
c. If the machine does not complete the above sequence correctly, check the screen
settings. If they are not correct, reset them and repeat the test. If the machine performs
correctly
, go to
Instruction 8.
7. If the machine
does not
complete the above sequence correctly, there is a failure in the
machine
’
s control circuit.
a
. Trained personnel must correct it. Immediately turn the machine off by pressing the red
Off
Switch and turning the Main Disconnect Switch to the
Off
position. The machine
’
s
Main Disconnect Switch must be locked in the
Off
position until repairs are begun
and
follow Lock-out/Tag-out procedures.
Do not
operate this machine until qualified personnel
have repaired the machine and the Conductive Mode has been properly tested.
Summary of Contents for Haeger 824 WindowTouch-4e
Page 1: ...17 00001 C Page 1 824 WindowTouch4e Operation Manual ...
Page 111: ...17 00001 C Page 111 155 Program Ends and returns to Main Screen ...
Page 136: ...17 00001 C Page 136 Parts List Main Assembly ...
Page 138: ...17 00001 C Page 138 Parts List MAS 350 Bowl Assembly ...
Page 141: ...17 00001 C Page 141 Parts List Quick Mount Assembly ...
Page 143: ...17 00001 C Page 143 Parts List Muti Shuttle 2 Assembly ...
Page 145: ...17 00001 C Page 145 Parts List HMI Arm Assembly ...
Page 147: ...17 00001 C Page 147 Parts List TIS Assembly ...
Page 153: ...17 00001 C Page 153 Parts List Hydraulic Cylinder Main Assembly ...
Page 155: ...17 00001 C Page 155 Parts List Electrical Cabinet High Low Voltage Assembly ...
Page 158: ...17 00001 C Page 158 Parts List Hydraulic Reservoir Assembly ...
Page 161: ...17 00001 C Page 161 Parts List Hydraulic Manifold Assembly ...