17-00001-C
Page | 22
Down/Up Footswitch
The Down/Up Footswitch is shielded and connected to the Haeger Hardware Insertion Machine by a
heavy duty cable. It contains both the Down and Up Footswitches.
When the Down Footswitch is depressed, the Upper Tool Holder moves down. If you remove your foot
from the Down Footswitch, the Upper Tool Holder will stop. If you depress the Down Footswitch again,
the downward motion will
start again.
In
Conductive Mode
, the Hardware Insertion Machine will complete one normal cycle of the insertion
process when the Down Footswitch is depressed and held down. Hold the Down Footswitch until the
Upper Tool Holder starts to go up again.
In the
Non-Conductive Mode
, when the Down Footswitch is depressed, the Hardware Insertion
Machine will lower the Upper Tool until it contacts the workpiece and then stop. The
Down Footswitch
must then be released. When the Down Footswitch is
depressed a second time
, the Hardware
Insertion Machine
will
exert the preset force
and then return to its Up position. Once the upward
travel starts, release the Down Footswitch.
When the Up Footswitch is depressed, the Upper Tool Holder moves up. If you remove your foot from
the Up Footswitch, the Upper Tool Holder will stop. If you depress the Up Footswitch again, the
upward motion will start again.
Make sure you read and
understand the Warning and
Safety Instructions in the
Introduction section of this manual and follow the
instructions for
testing the Safety System in the
Safety System section before attempting to operate this
Hardware
Insertion Machine.
NEVER depress t h e Down foot switch a second t i m e in Non- Conductive Mode
when your hands a r e in the tooling area.
Conductive Mode:
•
Turn key to the Right.
•
Key is removable in this position and should
not
stay with the machine
–
key should be kept
by a trained setup person or shop owner.
Non-Conductive Mode:
•
Turn key to the left.
Summary of Contents for Haeger 824 WindowTouch-4e
Page 1: ...17 00001 C Page 1 824 WindowTouch4e Operation Manual ...
Page 111: ...17 00001 C Page 111 155 Program Ends and returns to Main Screen ...
Page 136: ...17 00001 C Page 136 Parts List Main Assembly ...
Page 138: ...17 00001 C Page 138 Parts List MAS 350 Bowl Assembly ...
Page 141: ...17 00001 C Page 141 Parts List Quick Mount Assembly ...
Page 143: ...17 00001 C Page 143 Parts List Muti Shuttle 2 Assembly ...
Page 145: ...17 00001 C Page 145 Parts List HMI Arm Assembly ...
Page 147: ...17 00001 C Page 147 Parts List TIS Assembly ...
Page 153: ...17 00001 C Page 153 Parts List Hydraulic Cylinder Main Assembly ...
Page 155: ...17 00001 C Page 155 Parts List Electrical Cabinet High Low Voltage Assembly ...
Page 158: ...17 00001 C Page 158 Parts List Hydraulic Reservoir Assembly ...
Page 161: ...17 00001 C Page 161 Parts List Hydraulic Manifold Assembly ...