CHARGING STATION PELLENC CHARGING STATION
56_136922-B
4.1.3. POSITIONING OF THE POWER CABLE
Depending on the position of the charging station cabinet, the qualified electrician who connects it can change the
position of the power cable of the Charging station (refer to Section 4.3, “Changing the position of the power cable”).
4.2. ELECTRICAL INSTALLATION
Warning
Any intervention in the electrical box must be done by a professional electrician (risk of electric
shock).
The electrical network must be equipped with a 30mA differential circuit-breaker compliant with
electrical safety standards for protection of persons, and a C16 circuit-breaker with SECTIONING
SWITCH DEVICE to connect the charging station.
4.3. CHANGING THE POSITION OF THE POWER CABLE
1. To access the power cable, remove the 3 screws on
the vertical plate (at the bottom of the charging sta-
tion cabinet) using a screwdriver.
2. Remove the vertical plate.
16