Single Port for
WABTEC Next Gen
®
Instruction Manual
RRP-433 Charger
Single Port for
End of Train Device
plus
Battery Packs
~9 sec
STATUS Modes:
Healthy Battery [Mode 0]:
This is the normal mode for most batteries. Once the CHARGE cycle is
complete, the battery can be returned to service.
Battery Capacity Warning [MODE 1]:
After the charger has entered the Pulsed-Current float cycle, it will periodically
check the battery capacity - approximately once an hour. It does this by
stopping the top-up pulses for a short duration and checking the battery
terminal voltage response. If the battery terminal voltage drops below the
threshold level then the charger will go into [MODE 1]. Even if the unit
detects a low battery capacity, it will continue to charge the battery.
[MODE 1] is a warning that the battery capacity is getting low and may be
nearing the end of its usable life.
Before the battery is replaced, it should
be checked by a calibrated battery tester.
Defective or Disconnected Battery [MODE 2]:
If the battery is disconnected or is defective, the charger will go into [MODE 2]
and remain there until a healthy battery is connected.
The charger will not
charge a battery in this mode.
When a healthy battery is reconnected the
charger will return to [MODE 1] and begin the charging cycle, unless a problem
is detected.
Over Temperature [MODE 3]:
If a battery over temperature condition occurs, the charger will stop the charge
cycle and enter into [MODE 3]. The charger will periodically check the
temperature of the battery and if the temperature drops below the maximum
allowed temperature the charger will resume the charge cycle and return to
[MODE 1].
Over Current [MODE 4]:
If an over current / short circuit condition is detected, the charger will stop the
charge cycle and enter into [MODE 4]. This is considered a major fault condition.
To protect the battery and the charger itself, the charger will need to be powered
off and restarted to resume the charge cycle.
Charger Safety Features
Short Circuit Protection:
Protects the charger from short-circuit damage.
Over Current Protection
: Protects the charger from over-current demand.
Over Voltage Protection
:
Protects the battery pack from damage.
Battery Polarity Reversal
: Protects the charger and battery pack against
incorrectly installed batteries.
Low Battery Voltage
: When the battery pack falls below 7V, the charger will
not operate in Normal Charge Mode.
Charger Specifications
Input Voltage: 100-120VAC
Input Frequency: 47-63Hz
Output Voltage: @Fast Charge: 14.4VDC; Float: 13.6VDC
Output Current: DC 1,000mA (Fast Charge)
Battery Capacity: 5-20Ahr (recommended)
Operating Temp: +32F/0C to +104F/40C
Storage Temp: -4F/-20C to +140F/60C