35
ENGLISH |
E3H
HOUR OF THIRD LAST
ERROR
Hour third last error registered (referred to TH)
E4
FOURTH LAST ERROR
Fourth last error registered
E4H
HOUR OF PENULTIMA
ERROR
Hour fourth last error registered (referred to TH)
EE
ZERO SETTING ERRORS
Allows one to zero set the errors register; to zero set the
register press the SET button and keep it pressed until
“OK” appears on the display
(SET
Æ
****
Æ
OK)
TEST
To switch on and regulate the pump manually:
• Enter into TEST mode through access to the HIDDEN LISTS.
• Proceed as shown below to start up and adjust the speed of the pump.
• During the TEST it is possible to display all the operating parameters (through the display of the operating parameters).
INSTRUCTION
INSTRUCTION
DISPLAY
DISPLAY
TEST mode (the word TEST appears on the display)
TEST mode (the word TEST appears on the display)
TEST
Switch on the pump by pressing the OFF/ON switch;
Switch on the pump by pressing the OFF/ON switch;
the pump starts up at the minimum frequency
the pump starts up at the minimum frequency
P 2.0
Display the operating frequency by scrolling with the arrow
Display the operating frequency by scrolling with the arrow
F 30
Vary the operating frequency by 1 Hz at a time with the arrows
Vary the operating frequency by 1 Hz at a time with the arrows
F 35
Display the operating parameters with the arrows
Display the operating parameters with the arrows
A 3.5
At the end of the TEST switch off the pump by pressing the OFF/ON switch
At the end of the TEST switch off the pump by pressing the OFF/ON switch
OFF
Summary of Contents for TISSEL-100
Page 2: ......
Page 77: ...77 30 5 TISSEL 100 TISSEL 100 OFF ON...
Page 80: ...80 30 TISSEL 100 TISSEL 100 10 Qmax 80 V 80 x 10 8 70 Pset 4 4 x 70 2 8 TISSEL 100 230 50...
Page 83: ...83 BASIC P 2P A RO ADV d MF LF HF Td PF TPF TP TF RF FS US EI i...
Page 84: ...84 EO AI AT W V Pd iDRY FM FLAT SET F INSP WH TH NS SH E1 E1H E2 E2H E3 E3H E4 E4H EE TEST...
Page 94: ......
Page 95: ......