27
ENGLISH |
START UP
PRIMING OF THE PUMP
• Before switching on read the attached manual and follow the instructions, in order to avoid errors in settings and operations
which could cause anomalies in functioning.
• Do not switch on the pump when it is dry, not even for a few seconds.
• Before switching on the pump, prime the pump.
• Insert the plug in the socket.
• After 10 seconds the STARTING phase ends and TISSEL-100 re-
turns to the same operating conditions which it was in when it
was last switched off:
– IN SERVICE if when it was last switched off it was IN SERVICE.
– OUT OF SERVICE if when it was last switched off it was OUT
OF SERVICE (OFF).
In the case of an accidental fall in power, if TISSEL-100 was IN SERVICE (ON), when the power returns it will automatically return
to IN SERVICE (ON).
• To put TISSEL-100 in service press the key (1) ON/OFF on the control panel.
• TISSEL-100 starts to function.
• If the pump is not correctly primed place TISSEL-100 into the TEST mode (manual control) and gradually open the delivery
valve (for its functioning in TEST mode see the respective chapter later in this manual).
ATTENTION: the inverter is perfectly configured in accordance with the predefined factory settings, in order to function correctly
with the associated pump.
If it were necessary to modify the factory settings of the TISSEL-100 set the inverter using the parameters in the HIDDEN LIST (see
chapter SETTING UP PARAMETERS IN THE HIDDEN LISTS).
CONFIGURATION OF THE PARAMETERS
MODIFICATION OF THE PRESSURE OF THE SET
To increase by 0.1 bar
press both the keys at the same time
+
example:
P 3.2
Æ
P 3.3
To decrease by 0.1 bar
press both the keys at the same time
+
example:
P 3.2
Æ
P 3.1
VISUALISATION OF THE FUNCTION PARAMETERS
• To visualise the parameters on the display whilst it is functioning scroll with the keys
• By pressing the key
one returns to the visualisation of the pressure of the system on the display.
1
Summary of Contents for TISSEL-100
Page 2: ......
Page 77: ...77 30 5 TISSEL 100 TISSEL 100 OFF ON...
Page 80: ...80 30 TISSEL 100 TISSEL 100 10 Qmax 80 V 80 x 10 8 70 Pset 4 4 x 70 2 8 TISSEL 100 230 50...
Page 83: ...83 BASIC P 2P A RO ADV d MF LF HF Td PF TPF TP TF RF FS US EI i...
Page 84: ...84 EO AI AT W V Pd iDRY FM FLAT SET F INSP WH TH NS SH E1 E1H E2 E2H E3 E3H E4 E4H EE TEST...
Page 94: ......
Page 95: ......