46
Note:
1. If the voltage range is not known beforehand set the function
switch to
the highest range and work down.
2. When only the figure "OL" is displayed, overrange is being
indicated and you must be set to a higher range.
3.
CAUTION
: Do not apply more than 600V to the input.
Indication is
possible at higher voltages but there is danger
of damaging the internal circuitry.
4. Use extreme caution to avoid contact with high tension circuits
when
measuring high voltage.
6.3. AC Voltage Measurement
1.
Connect the black test lead to the COM jack and the red
test lead to the V/
Ω- jack.
2.
Set Function Switch to V ~.
3.
Connect the test leads across the source of load under
measurement.
Note:
1.
If the voltage range is not known beforehand set the
function switch to
the highest range and work down.
2.
Caution
: Do not apply more than 600V
rms
to the input.
Indication is possible at higher voltages but there is danger
of damaging the internal circuitry.
3.
Use extreme caution to avoid contact with high tension
circuits when measuring high voltage.