39
4. Specifications
Accuracies are: (% of r no. of digits) guaranteed for 1
year, 23°C +/- 5°, less than 75% RH
4.1. DC Voltage
Range
Resolution Accuracy
400 mV
0,1 mV
+/-1,0% rdg. + 4 dgt.
4 V
1 mV
40 V
10 mV
400 V
100 mV
+/-1,5% rdg. + 4 dgt.
600 V
1 V
Overload protection: 600V DC / AC
rms
Input Impedance: 10M
4.2. AC Voltage
Range
Resolution Accuracy
400 mV
0,1 mV
+/-1,5% rdg. + 15 dgt
4 V
1 mV
+/-1,0% rdg. + 4 dgt.
40 V
10 mV
400 V
100 mV
+/-1,5% rdg. + 4 dgt
600 V
1 V
+/-2,0% rdg. + 4 dgt.
Overload protection: 600V DC / AC
rms
Frequency Range: 50
– 400Hz
Input Impedance: 10M