- 87 -
13. Specification
Unless otherwise stated, the technical specifications only apply to probe damping to 10X. Only if
the oscilloscope first meets the following two conditions can these specification standards be
achieved.
The device should run continously for 30 minutes
Perform “Self-calibration” if the operating temperature changes by up to or even more than 5
℃
(see “Performing Self-Calibration”)
All technical data, with the exception of thos
e labeled “typical”, can be met
Description
Specifications
Bandwidth
P 1206
P 1207
P 1211
P 1212
70 MHz
120 MHz
70 MHz
100 MHz
Channels
P 1206
P 1207
P 1211
P 1212
2 CH
2 CH
4 CH
4 CH
Vertical resolution (A/D)
P 1206
P 1207
P 1211
P 1212
8 bit
8 bit
8 bit
8 bit
Acquire
Mode
Normal, Peak Detect, Average
Waveform sample
rate
45.000 wfms/s
Sampling rate
P 1206
P 1207
P 1211
P 1212
1CH / 2 CH
1CH / 2 CH
1CH / 2 CH / 4 CH
1CH / 2 CH / 4 CH
1 GSa/s, 500 MSa/s
1 GSa/s, 500 MSa/s
1 GSa/s, 500 MSa/s, 250 MSa/s
1 GSa/s, 500 MSa/s, 250 MSa/s
Input
Input coupling
DC, AC, Ground
Input impedance
1 MΩ±2%, in parallel with 15 pF±5 pF
Probe attenuation
factor
0.001X - 1000X, 1
– 2 – 5 steps
Max. input voltage
400 V (DC + AC Peak)
Bandwidth limit
20 MHz, full bandwidth