Warranties and Liabilities

1.  The Company warrants that it has title to the Goods.
2.  Subject to the provisions of this clause the Company warrants that the Goods  

 

shall comply in all material respects with any specification referred to in the Order  

Confirmation (as the same may be amended) and shall, subject thereto, be free    

from defects in material and workmanship for the lesser of a period of twelve  

 

months from the date of delivery or thirteen months from the date of dispatch    

from the factory.

3.  Save as provided in this clause and except where the Goods are sold to a person   

dealing as a consumer (within the meaning of the Unfair Contract Terms Act  

 

1977) all warranties, conditions or other terms implied by statute or common  

law are hereby expressly excluded save to the extent they may not be lawfully 

excluded. When the Goods are sold to a consumer within the meaning of the Unfair 

Contract Terms Act 1977 their statutory rights are not affected by the provisions of 

this clause.

4.  In the event of the Customer making a claim in respect of any defect in terms of   

clause 2 hereof the Customer must. 

1.  Reasonably satisfy the Company that the Goods have been properly installed, 

commissioned, stored, serviced and used and without prejudice to the generality 

of the foregoing that any defect is not the direct or indirect result of lack of repair 

and/or servicing, incorrect repair and/or servicing, use of wrong materials and/or 

incorrect spare parts 

2.  Allow the company to inspect the Goods and/or any installation and any relevant 

packaging as and when reasonably required by the Company.

5.  Subject to the Company being notified of any defect as is referred to in sub- 

 

clause 2 hereof within a reasonable time of it becoming apparent and subject always 

to the terms of sub-clause 4 hereof, the Company shall, in its option, replace or 

repair the defective Goods or refund a proportionate part of the Price. The Company 

shall have no further liability to the Customer (save as mentioned in sub-clause 6 

hereof).

6.  The Company shall be liable to indemnify the Customer in respect of any claim 

for death or personal injury to any person in so far as such is attributable to the 

negligence or breach of duty of the Company or any failure by the Company to 

comply with the provisions of sub-clause 2 hereof.

7.  Save as provided in sub-clause 2 hereof the Company shall not be liable in respect 

of any claim by the Customer for costs, damages, loss or expenses (whether direct, 

indirect, consequential or otherwise) or indemnity in any respect howsoever arising 

including, but not by way of limitation, liability arising in negligence (other than 

pursuant to clause 6 above) that may be suffered by the Customer or any third 

party.

Summary of Contents for Solaris XE

Page 1: ...Solaris XE User Manual Copyright Peak Scientific Instruments Ltd 2020 Solaris XE User Manual Rev 5 RSID 2302 EN 21 07 2020...

Page 2: ...Kit Contents 10 Unpacking Instructions 10 Installation 11 Generator Environment 11 Generator Overview 12 Solaris XE General Dimensions 12 Solaris XE Rear Connections 13 Electrical Connection 14 Air P...

Page 3: ...ntended for end users and has been written as a reference document where you can skip to the relevant information Users can refer to the contents page to find the relevant information Please review ea...

Page 4: ...ality of the foregoing that any defect is not the direct or indirect result of lack of repair and or servicing incorrect repair and or servicing use of wrong materials and or incorrect spare parts 2 A...

Page 5: ...ted conditions are fully understood or met A CAUTION notice denotes a hazard It calls attention to an operating procedure process or similar which if not correctly performed or adhered to could cause...

Page 6: ...10 Electrical Equipment for measurement control and laboratory use Electromagnetic Compatibility Directive 2014 30 EU EN 61326 1 2013 Electrical Equipment for measurement control and laboratory use FC...

Page 7: ...onfirm that as a manufacturer of articles we conform to the European Parliament and Council Directives 2011 65 EU for the original 6 restricted substances listed in the Restriction of Hazardous Substa...

Page 8: ...Flow For Max Outlet Flow up to 100 L min Minimum Air Inlet Quality ISO 8573 1 2010 Class 1 4 1 Generator Outlets Maximum Output Pressure 116 psi 7 99 bar variable Maximum Outlet Flow Rate up to 35 L m...

Page 9: ...k Partner from where the unit was purchased Follow the unpacking instructions posted on the side of the crate It will require two people to remove the unit from the shipping crate and to manoeuvre the...

Page 10: ...Key x 1 10 No 8 Wall Plug x 4 11 No 8 Screw x 4 All of the generators output ports are located on the rear panel of the unit Unpacking Instructions The unit weight constitutes a two person lift and a...

Page 11: ...ths of pipe runs as pressure drops can result from extended runs of pipe The performance of the generator like all sophisticated equipment is affected by ambient conditions Note should also be taken t...

Page 12: ...Page 12 Generator Overview Solaris XE General Dimensions Horizontal postioning on wall 343 mm 13 50 655 mm 25 78 156 mm 6 14...

Page 13: ...ts are connected to correct application Connections should only be carried out by trained personnel The Generator should be switched off prior to maintenance and cleaning Power Switch Power Inlet Nitr...

Page 14: ...se check that your electrical supply falls within the specified range see below EARTH GROUND E Green Yellow or Green LIVE L Brown or Black Neutral N Blue or White Electrical requirements are 100 230VA...

Page 15: ...tion to ensure correct tubing is being used Once the tubing is connected to the application please ensure that it is thoroughly checked for being leak tight Even the slightest leak in the gas supply b...

Page 16: ...ive an indication of internal pressure in the system The LED s on the front panel will illuminate YELLOW Turn the air supply on The fascia will illuminate GREEN when adequate system pressure has reach...

Page 17: ...the regulator at the front of the generator and viewed on the adjacent gauge To access the regulator unclip the fascia from the unit Adjust the gauge to the required pressure To ensure a smooth press...

Page 18: ...uirements Service Schedule Purchase Interval Component Visit Qty 12 months Solaris Nitrogen XE Annual Maintenance Kit www peakscientific com ordering 1 Please note Only Peak Scientific approved compon...

Page 19: ...to install and setup your generator IQ OQ Certified assurance for applications requiring documented qualification Complete plan Swift response by a Peak Service Engineer within 72 hours planned preve...

Page 20: ...e cloth prior to use Cleaning should only be undertaken with the power switched off and the power cord removed from the rear of the generator Under no circumstances should any solvents or abrasive cle...

Page 21: ...rd plug Contact your service provider The fascia LED s have not illuminated but the power switch is illuminated Contact your service provider The fascia Yellow illumination does not change to green Ch...

Page 22: ...ic com For generators that remain unregistered after 1 month from the shipment date the warranty will be considered active from the date of factory dispatch Complete Plan only Go Online or Complete an...

Page 23: ...Page 23...

Page 24: ...ponse service to our customers With Peak Protected your laboratory s productivity becomes our top priority To discuss Peak Protected generator cover and payment options speak to your local Peak Repres...

Reviews: