background image

 

 

2013 © Peak Scientific – Rev 4 – 03/09/1 

 

 

 

 

 

 

Peak Scientific UK 

Fountain Crescent 
Inchinnan Business Park 
Inchinnan 
PA4 9RE 
Scotland, UK 

Peak Scientific North America 

19 Sterling Road 
Suite #1 
Billerica, MA 01862 
 
USA 

Peak Scientific India 

202, Amsri Shamira 
Old Lancer Line 
Opp. St. Mary’s Degree College 
S.D. Road Secunderabad 
500 025, India 

Peak Scientific Africa 

PO Box 478 
Somerset Mall 
7137 
  
South Africa 

Tel:

  +44 (0)141 812 8100 

Fax:

 +44 (0)141 812 8200 

Tel:

  +1 866 647 1649 

Fax:

 +1 978 608 9503 

Tel:

  +91 40 2780 0663 

Fax:

 +91 40 2780 0663 

Tel:

  +27 (0)2185 16542 

Fax:

 +27 (0)8654 64473 

 

 

 

 

Peak Scientific Germany 

Herriotstrasse 1 
60528 Frankfurt 
 
 
Germany 

Peak Scientific China 

Room 606 Building 1  
Lane 2277 Zuchongzhi Road  
Pudong New Area  
Shanghai 
201203, China 
 

Peak Scientific Mexico 

Solon 352 
Col. Los Morales Polanco 
11530 Mexico, D.F. 
 
Mexico 

Peak Scientific Australia 

PO Box 65 
Belmont 
Victoria 3216 
 
Australia 
 

Tel:

  +49 (0)69 677 33 490 

Fax:

 +49 (0)69 677 33 200 

Tel:

  +86 21 5079 1190 

Fax:

 +86 21 5079 1191 

Tel:

  

  

+1 866 647 1649

 

Fax:

 

  

+1 978 608 9503 

Tel:

  

  

+61 1300 965 352 

 
 

Peak Scientific Taiwan 

4F.-6, No.736 
Zhongzheng Rd. 
Zhonghe Dist.  
New Taipei City 
 

+886 2 8226 2383 

Tel:  

+886 2 8226 9499 

Fax

Peak Scientific Brazil 

Peak Scientific Brasil 
Av. Quieroz Filho 
1700 – torre Sunny-Conj. 602 
São Paulo SP Brasil 

 
Tel:  

+1 866 647 1649

 

 
 

Peak Scientific Japan K.K. 

2-7-56, 2F Fuji Building 28 
Kita Aoyama, Minato-Ku 
Tokyo, Japan 
107-0061 

 
Tel:  

+81 3-6864-0468

 

Peak Scientific Singapore 

3 Science Park Drive 
#03-14 The Franklin 
Science Park Drive 1 
Singapore, 118223 

 
Tel:  

+65-6777 1966

 

Fax: 

+65-6777 1978

 

Summary of Contents for Hydrogen Detector

Page 1: ...Hydrogen Detector User Manual 2021 Peak Scientific Rev 5 12 10 2021...

Page 2: ...pecification 9 Environment 9 Detector Inlets 9 Default Configuration 9 Electrical Requirements 9 General 9 Unpacking 10 Installation 11 Detector Environment 11 General Dimensions 12 Rear Connections 1...

Page 3: ...llation and usage or as a reference document where you can skip to the relevant information Users of a hard copy version can refer to the contents page to find the relevant information Users of the so...

Page 4: ...ven to a sensor cartridge that is located inside the detector s chassis Our Hydrogen Detector is wall mountable and displays gas concentration alarm fault and status information via its backlit LCD an...

Page 5: ...to the generality of the foregoing that any defect is not the direct or indirect result of lack of repair and or servicing incorrect repair and or servicing use of wrong materials and or incorrect spa...

Page 6: ...k Act 1974 and the Institute of Electrical Engineers regulations If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment maybe impaired A WARNIN...

Page 7: ...2010 Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use Electromagnetic Compatibility Directive 2014 30 EU EN 61326 1 2013 Electrical Equipment for Measurement Co...

Page 8: ...ety Regulations 2016 SI 2016 1101 as amended BS61010 1 2010 Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use The Electromagnetic Compatibility Regulations 2016 S...

Page 9: ...ance Notes PDF produced by the Department for Business Innovation and skills for the UK and here for Europe All PEAK products that are subject to the WEEE directive are compliant with the WEEE marking...

Page 10: ...lue TLV 100 Lower Explosive Limit LEL 25 Volume v v Lowest Alarm Level LAL Typically TLV 10 LEL 5 v v Lower Detectable Level LDL Typically 0 4 TLV 9 LEL 0 v v The LDL is the minimum level that is reli...

Page 11: ...of rough handling prior to un packing Any damage should be reported immediately to the carrier and Peak Scientific or the Peak Partner from where the unit was purchased Please save the product packagi...

Page 12: ...could adversely affect its performance Please refer to the drawing below for the general dimensions of the unit Maximum Ambient Conditions 40 C dry bulb 90 RH Max Non Condensing Location The detector...

Page 13: ...H Detector User Manual Page 12 2013 Peak Scientific Rev 4 03 09 1 General Dimensions The Detector must always be placed on a level surface Failure to do so will affect the performance of the Detector...

Page 14: ...HK Exhaust Tubing 1 5m 6 OD x 3 16 THK Input Tubing 1 5m 7 OD Stainless Steel Tubing x 1m 8 Bulkhead Reducer Fitting x 1 9 Tygon Filter Tubing x 1m 10 Hex Key x 1 11 Hose Clips x 2 12 Wall Mounting Br...

Page 15: ...late directly above the rear hole on the GC oven 3 Make a hole through the insulation material through to the oven The stainless steel tubing from the detector can now be pushed through the hole and s...

Page 16: ...alarm if dangerous levels of Hydrogen are detected The generator will then shut down Tubing Lengths The length of the tubing which will be connected to the Input Port of the Detector is important and...

Page 17: ...cation between the Precision 500 and the detector unit The detector will take samples continuously and both the detector and the Precision 500 will alarm if dangerous levels of hydrogen are detected t...

Page 18: ...in place by two locking tabs Some cartridges are shipped with a protective cap to shield them from contaminants during shipping This cap must be removed before inserting the cartridge into the Detecto...

Page 19: ...he display hit the on the Detector front panel 2 When the reboot completes then press and hold the X to clear any latched fault s 3 Confirm that the green LED is flashing 4 Confirm that the yellow and...

Page 20: ...messages WAIT and LOAD as it checks for the cartridge data typically less than 180 seconds 4 When complete the detector will enter normal monitoring mode indicated by the icon on the display cycling...

Page 21: ...EMAIL ADDRESS CITY TOWN DETECTOR SERIAL NUMBER POSTCODE COUNTRY MODEL TYPE TELEPHONE INSTALLATION DATE DD MM YYYY Important Please Note You have 1 month to register your Peak Scientific product from...

Page 22: ...rent is degrading the ability of the Detector to detect gas Check application Contect Peak Service Provider M15 Temperature Near Limit Temperature within 2 Celsius of limit Check installation environm...

Page 23: ...Cartridge Replace Cartridge Contact Peak Service Provider F49 Cartridge Wrong Type Cartridge type found to be incorrect after boot up Replace Cartridge or press to accept if correct Contact Peak Serv...

Page 24: ...1 Lane 2277 Zuchongzhi Road Pudong New Area Shanghai 201203 China Peak Scientific Mexico Solon 352 Col Los Morales Polanco 11530 Mexico D F Mexico Peak Scientific Australia PO Box 65 Belmont Victoria...

Reviews: