background image

Page 5

Warranties and Liabilities

     

Warranty & Liability Coverage

1.  Peak warrants that, subject to the provisions in this statement, purchased Peak generators, whether 

purchased directly from Peak or indirectly via an approved, certified and trained distributor or partner 
(referred to hereafter as a “Peak Partner”) will comply in all material respects with any specifications 
referred to in your customer order confirmation and, subject to installation and operational guidelines 
being followed as described in applicable product manuals, shall be free from any defects in quality 
of materials or workmanship for a period of one year from the date of installation, provided this takes 
place within 3 months of factory dispatch.

2.  Where the purchased generator is from the Precision Hydrogen series, Peak further warrants that, 

subject to installation and operational guidelines being followed as described in applicable product 
manuals, the hydrogen cell shall be free from any defects in quality of materials or workmanship for a 
total period of three years (inclusive of warranty period specified in clause 1) from date of installation, 
provided this takes place within 3 months of factory dispatch.

3.  Where the purchased generator is from the i-Flow 6000 series, Peak further warrants that, subject 

to installation and operational guidelines being followed as described in applicable product manuals, 
the generator shall be free from any defects in quality of materials or workmanship for a total period 
of two years (inclusive of warranty period specified in clause 1) from the date of installation, provided 
this takes place within 3 months of factory dispatch and the following provisions have also been met:                
a. you must purchase a service plan, ensuring the generator is serviced by Peak or a Peak Partner on 
or before the end of the first 12 months of your ownership, and serviced at least once during each 
subsequent 12 month period thereafter;  
b. the generator (and any associated equipment) must have been commissioned by Peak or a Peak 
Partner; 
c. the feed air or inlet air supply to the generator must comply with ISO 8573-1:2010 Class 1.2.1 at all 
times; 
d. your air compressor, dryer, filtration and oil removal systems must be deemed suitable for use by 
Peak or a Peak Partner, and must be changed and serviced regularly, in line with the equipment man-
ufacturer’s recommended guidelines; and 
e. any generator failure or fault that is deemed to have been caused by the failure of any upstream 
equipment, component, part or system (such as air compressor, air treatment or filtration) will be 
excluded from the warranty described herein.

4.  Where the purchased generator is from the Genius XE range, Peak further warrants that, subject to 

installation and operational guidelines being followed as described in applicable product manuals, the 
generator shall be free from any defects in quality of materials or workmanship for a total period of 
two years (inclusive of warranty period specified in clause 1) from the date of registration, provided 
the following provisions have also been met: 
a. The product must be registered within 12 months of the build date, to the end user (registrations to 
3rd party resellers or other channel partners will not qualify for the warranty extension). 
b. You must purchase a service plan, ensuring the generator is serviced by Peak or a Peak Partner on 
or before the end of the first 13 months of your ownership 
c. The product is required to be serviced in accordance with manufacturer requirements, preventative 
maintenance visit must be arranged within 13 months of installation, and the generator must be ser-
viced by Peak, or a Peak Partner within 13 months of installation. 
d. Products purchased via Peak Partners may be subject to call-out and labor charges, which is at the 
discretion of the Peak Partner.

5.  Peak also warrants that any replacement parts whether purchased (directly from Peak, or via a Peak 

Partner) or supplied as part of any remedial action undertaken in line with the provisions of clauses 13 
and 14, shall be free from any defects in quality of materials or workmanship for a period of 180 days 
from the date of factory dispatch, provided its installation is performed by Peak or a Peak Partner. 

6.  This warranty does not exclude Peak’s liability in respect of any claim for death or personal injury to 

Summary of Contents for Genius XE SMZ

Page 1: ...Genius XE SMZ User Manual Rev 1 RSID 4041 EN 09 02 21 Genius XE SMZ User Manual...

Page 2: ...ranty your generator must be registered to the end user not a reseller or distributor and must have a paid annual preventative maintenance arranged within 13 months of the installation date carried ou...

Page 3: ...onment 13 Generator Overview 14 General Dimensions 14 Genius XE SMZ Rear Connections 15 Drain Connection 16 Electrical Connection 17 Start Up Sequence 18 Connecting to the application 19 Tubing Length...

Page 4: ...ant information Users can refer to the contents page to find the relevant information Please review each of the following sections carefully Thank you for selecting Peak Scientific to meet your gas ge...

Page 5: ...upply to the generator must comply with ISO 8573 1 2010 Class 1 2 1 at all times d your air compressor dryer filtration and oil removal systems must be deemed suitable for use by Peak or a Peak Partne...

Page 6: ...nd conditions outlined in this warranty state ment in any respect or to create any additional obligations or liabilities for any party involved 6 This warranty statement supersedes any and all prior w...

Page 7: ...ted conditions are fully understood or met A CAUTION notice denotes a hazard It calls attention to an operating procedure process or similar which if not correctly performed or adhered to could cause...

Page 8: ...for Electrical Equipment for Measurement Control and Laboratory Use Electromagnetic Compatibility Directive 2014 30 EU EN 61326 1 2013 Electrical Equipment for Measurement Control and Laboratory Use...

Page 9: ...onfirm that as a manufacturer of articles we conform to the European Parliament and Council Directives 2011 65 EU for the original 6 restricted substances listed in the Restriction of Hazardous Substa...

Page 10: ...hours before operation Generator Outlets Nitrogen Maximum Flow 27 L min 6 89 bar 0 95 cfm 100 psi Air Maximum Flow 29 L min 6 89 bar 1 02 cfm 100 psi Particles 0 01 m Phthalates NONE Suspended Liquids...

Page 11: ...e Peak Partner from where the unit was purchased Follow the unpacking instructions posted on the side of the crate It will require two people to remove the unit from the shipping crate and to manoeuvr...

Page 12: ...ngs Kit are as follows 1 Teflon Tubing x 3m x 3 2 6mm PE Tubing x 3m x 3 3 Compression Fitting x 2 4 6mm Push Fit Fitting x 3 5 Flow Control Silencer x 2 6 UK Mains Power Cable 230v x 1 7 EU Mains Pow...

Page 13: ...of THC additional THC removal filtration may be required or service life of integrated THC traps may be significantly reduced Note should also be taken to the proximity of Air Conditioning outlets Th...

Page 14: ...4 Generator Overview General Dimensions The generator must always be placed on a flat level surface Failure to do so will affect the performance of the generator WARNING 570 mm 22 4 897 mm 35 3 700 mm...

Page 15: ...o correct sources and applications All Connections should only be carried out by trained personnel Generator must be switched off and unplugged prior to any cleaning or maintenance operations IEC Powe...

Page 16: ...ater from this dependant on ambient humidity If a container is used it should be emptied at regular intervals The container must NOT have an air tight seal as water and air are expelled at pressure Wh...

Page 17: ...nerator or risk overloading of the power cord This unit is classified as SAFETY CLASS 1 THIS UNIT MUST BE EARTHED Before connecting the unit to the mains supply please check the information on the ser...

Page 18: ...is reached the compressors will continue to run until the internal tank upper pressure limit is reached and the compressor has run for a period of at least two minutes The compressors will then rest u...

Page 19: ...leak in the gas supply between the generator and the application can lead to a reduction in efficiency Tubing Lengths The diameter of the tubing which will be connected to the gas outlets is importan...

Page 20: ...erator is designed to operate in either a cyclic mode or run continuously this will be dependent on the output flow The cyclic rate of the compressors will depend on the gas demand of the application...

Page 21: ...ed on it will show the following screens until a system check has been performed The checks will last a few seconds then the HMI will show the home screen Customers can view two screens at this stage...

Page 22: ...is due the LED on the front panel will illuminate and the internal HMI will show the following screens When a service is overdue the HMI will show the following screens Service due date can be checked...

Page 23: ...er warning signal along with a fault reference code Toggle the warning indicator in the top right corner of the HMI to view warning code A list of fault codes for the SMZ is shown below REF CODE 0006...

Page 24: ...isplay a red warning signal along with a fault reference code Toggle the warning indicator in the top right corner of the HMI to view warning code A list of major fault codes for the SMZ is shown belo...

Page 25: ...nths Genius XE SMZ Annual Maintenance Kit www peakscientific com ordering 4 Years Genius XE SMZ Year 4 Service Kit www peakscientific com ordering Please quote your generator serial number when orderi...

Page 26: ...ing Stage 2 If the service is not completed the generator will continue to run After 2 weeks the service HMI will show a service icon This is to make the user aware that the service of the generator i...

Page 27: ...to install and setup your generator IQ OQ Certified assurance for applications requiring documented qualification Complete plan Swift response by a Peak Service Engineer within 72 hours planned preve...

Page 28: ...e cloth prior to use Cleaning should only be undertaken with the power switched off and the power cord removed from the rear of the generator Under no circumstances should any solvents or abrasive cle...

Page 29: ...uminate Ensure power cord is plugged into the Generator and that the power socket is turned on Check the fuse in the power cord plug Contact your service provider Compressors are running but pressure...

Page 30: ...Page 30...

Page 31: ...Page 31...

Page 32: ...ustry leading rapid response service to our customers With Peak Protected your laboratory s productivity becomes our top priority To discuss Peak Protected generator cover and payment options speak to...

Reviews: