Microdrive Series Instruction Manual
4201-109 Rev I
32
Table 1.1
Display Screen Messages - Short Menus
STATUS LINE - PERMANENT STATUS MESSAGE
SCREEN:
XXX Y 0.0A +0.0HZ
XXX
Y (FLASHING)
STP =
STOPPED
i
= CURRENT EXCEEDS DRIVE RATING
SPG =
STOPPING
m
= CURRENT EXCEEDS MOTOR CAPABILITY
RDY =
READY
RUN =
RUN
INC =
INCHING
ACC =
ACCELERATING
0.0A = OUTPUT CURRENT
DEC =
DECELERATING
ILT =
CURRENT LIMITING
+0.0Hz = OUTPUT FREQUENCY
VLT =
VOLTAGE LIMITING
HST =
HOST STOP (SERIAL COMMS.)
FLT =
FAULT TRIP
CONTROL STATUS DISPLAY (SCREEN -3)
The Control Status Display directly indicates the status of all control inputs
00000000 00 00
12345678 Vdc mA
CODE
FUNCTION
INPUT
DISPLAY INDICATION
1
MULTIFUNCTION 1
T8
0 = LOW ; 1 = HIGH
2
MULTIFUNCTION 2
T9
0 = LOW ; 1 = HIGH
3
MULTIFUNCTION 3
T10
0 = LOW ; 1 = HIGH
4
MULTIFUNCTION 4
T11
0 = LOW ; 1 = HIGH
5
MULTIFUNCTION 5
T12
0 = LOW ; 1 = HIGH
6
MOTOR PTC
T14
0 = LOW ; 1 = HIGH
7
PULSE TACHO
T17
0 = LOW ; 1 = HIGH
8
RX (SERIAL COMMS.)
0 = LOW ; 1 = HIGH
Vdc
0-10Vdc
T20
0 - 100(%)= 0-10Vdc
mA
4-20mA
T22
0 - 100(%)= 4-20mA
FAULT MESSAGES (SCREEN 2)
Fault messages are automatically shown on the second line of the display.
SCREEN
DESCRIPTION
TRIP POINT (NOTES)
NO FAULTS
NO FAULTS PRESENT
-
LVDC SUPPLY LOW
FAILURE OF +24V OR +15V SUPPLIES
22V/12V
SUPPLY FAULT
INPUT PHASE VOLTAGE IMBALANCE
40Vac IN DC BUS
OVERVOLTAGE TRIP
DC BUS OVERVOLTAGE
800Vdc
LOW MAINS SUPPLY
LOW MAINS SUPPLY
400Vdc/280Vac
O/P I IMBALANCE
OUTPUT CURRENT IMBALANCE
+/- 30%
OVERCURRENT TRIP
EXCESSIVE OUTPUT CURRENT
180% OF RATED CURRENT
IGBT/SLAVE FAULT
MAIN SEMICONDUCTOR OVERLOAD
SHORT CIRCUIT / OTHER
BRAKE THERM TRIP
DYNAMIC BRAKE OVERLOAD
SET BY BRAKE THERMAL MODEL
MOTOR THERM TRIP
MOTOR THERMAL MODEL OVERLOAD
SET BY MOTOR THERMAL MODEL
MOTOR MICROTHERM
MOTOR THERMAL SENSOR TRIP
SET BY MOTOR SENSOR
DRIVE THERM TRIP
DRIVE THERMAL MODEL OVERLOAD
SET BY DRIVE THERMAL MODEL
DRIVE MICROTHERM
HEATSINK TOO HOT
90 DEG CELSIUS
MOTOR STALLED
MOTOR STALLED FOR TOO LONG
ILT T/O (SEE SCREEN 19)
GROUND FAULT
GROUND FAULT ON DRIVE OUTPUT
INTERNALLY SET
CALIBRATION FLT
INTERNAL DRIVE FAULT
(REQUIRES SERVICE)
DATA CORRUPTED
NON-VOLATILE MEMORY ERROR
(ALL DRIVE DATA IS RESET)
EEPROM FAILURE
INTERNAL FAULT
(REQUIRES SERVICE)
INVALID SOFTWARE
INCORRECT VERSION EPROM
(REQUIRES SERVICE)
HOST TRIP
HOST COMPUTER TRIP
-
COMMS TIMEOUT
SERIAL COMMUNICATIONS TIMEOUT
COMMS T/O (SEE SCREEN 74)
Summary of Contents for D3-2.5
Page 2: ...Microdrive Series Instruction Manual 4201 109 Rev I 4201 003 Rev A Page 2 of 12...
Page 6: ...Microdrive Series Instruction Manual 4201 109 Rev I 4201 003 Rev A Page 6 of 12...
Page 12: ...Microdrive Series Instruction Manual 4201 109 Rev I 4201 003 Rev A Page 12 of 12...
Page 55: ...Microdrive Series Instruction Manual 4201 109 Rev I 55...
Page 74: ...Microdrive Series Instruction Manual 4201 109 Rev I 74...
Page 75: ...Microdrive Series Instruction Manual 4201 109 Rev I 75...
Page 76: ...Microdrive Series Instruction Manual 4201 109 Rev I 76...
Page 77: ...Microdrive Series Instruction Manual 4201 109 Rev I 77...
Page 78: ...Microdrive Series Instruction Manual 4201 109 Rev I 78...
Page 79: ...Microdrive Series Instruction Manual 4201 109 Rev I 79...
Page 80: ...Microdrive Series Instruction Manual 4201 109 Rev I 80...
Page 81: ...Microdrive Series Instruction Manual 4201 109 Rev I 81...
Page 82: ...Microdrive Series Instruction Manual 4201 109 Rev I 82...
Page 83: ...Microdrive Series Instruction Manual 4201 109 Rev I 83...
Page 112: ...Microdrive Series Instruction Manual 4201 109 Rev I 112...
Page 113: ...Microdrive Series Instruction Manual 4201 109 Rev I 113...