Programming Channels 

Three different Service Levels (banks) are available to hold channels: Free, Basic, and Premium.  
A Disable Service level is provided to remove the TV from service.  Channels can be 
programmed using either an Automatic or Manual method. 
 

AUTO PROGRAM 

Automatically memorizes all the receivable channels on a hospital’s cable TV system. 
Press the 

MENU

 button on the remote. 

1. Select 

the 

Setup

 menu. 

2. Select 

Auto Program

3. Press 

the 

CH

▲▼

 button and select 

Table

4.  Select the TV cable system in your hospital with the 

VOL

◄►

 

button.  

NOTE: Table = V/UHF is used for a cable system that 
has a master antenna and usually can only receive 
local TV Stations. 
Table = Cable is used when a hospital cable system 
has both local and satellite TV channels available.  
Table mode = Cable is most common in hospital TV 
systems. 

5.  Select the desired 

Service Level

 to be programmed. 

6. Select 

the 

Start 

menu item with the 

CH

▲▼

 button. 

7. Press 

the 

VOL

◄►

 

button to start Auto Programming.  The TV will now search all 

available channels looking for signals and memorizing those channels that are active.  
Occasionally, strong over-the-air stations sneak onto the cable system.  To remove 
unwanted channels see Manual

 

Program

.   

8. Press 

the 

MENU

 button to finish auto programming.

 

9. Press 

the 

TV/AV

 button to return to normal TV viewing.

 

 

HINTS 

• 

Press the 

CH

▲▼

 buttons to check the memorized channels after auto programming is 

finished. 

• 

If you press the MENU button during auto programming, the function will stop and only 
channels programmed up to that point in time will remain. 

• 

The auto programming function can memorize only those channels which are active at the 
time of programming.  For example, a hospital educational channel may not be actively 
playing a tape and would not be memorized using auto program.   See the Manual Program 
section for adding and deleting channels. 

• 

Each service level is listed showing their current condition as either Programmed or Blank. 

 
 

MANUAL PROGRAM 

Manual Program allows you to manually add or delete channels 
within a particular Service Level and also add or edit channel 
name labels. 

1.  Tune to the channel you wish to add or delete.  Press 

the 

MENU

 button. 

2. Select 

the 

Setup

 menu. 

3. Select 

the 

Manual

 

Program

 menu. 

4. Press 

the 

VOL

◄►

 

buttons or directly enter the 

channel numbers using the remote control. 

5. Press 

the 

CH

▲▼

 buttons to select 

Table 

if necessary.  

Usually Table does not require adjustment. 

Position: 

▲▼

                 Next: 

◄►

 

Back : MENU              Exit : TV/AV 

Channel                                   2 
Table                                Cable 
Edit Name                              

 

Service Level                     Free 
Storage                                 On 

Manual Program 

Position: 

▲▼

             Adjust : 

◄►

 

Back : MENU              Exit : TV/AV 

Table                                 Cable 
Start    
Service Level                       Free  
Free                        Programmed     
Basic                                  Blank 
Premium                            Blank 

Auto Program 

Summary of Contents for PDI-P15LCDB

Page 1: ...96 Rev 2 1 User Manual Communication Systems Inc 40 Greenwood Lane Springboro Ohio 45066 PH 937 743 6010 FX 937 743 5664 http www pdiarm com PDI P15LCDB ARM PDI P15LCDB WR Model PDI P15LCDB LCD TV Com...

Page 2: ...ll the cable TV systems installer s attention to Article 820 40 of the National Electrical Code The code provides guidelines for proper grounding and in particular specifies that the cable ground shal...

Page 3: ...ower cord and do not place the set where the power cord is subject to damage REGULATORY INFORMATION FCC This equipment has been tested and found to comply with the limits for a Class B digital device...

Page 4: ...for long period of time 14 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid h...

Page 5: ...ts 5 Supplied Accessories 6 Arm Installation 7 Wall Installation 9 Remote 12 Controls 13 Connections 13 Menu Tree 17 Programming Channels 19 Picture 20 Sound 21 Special 23 Parental Control 26 MPAA Rat...

Page 6: ...6 Rev 2 6 Supplied Accessories The follow accessories are provided with the Product 1 AC Cord Wall Mount Model Only 2 AC DC Adaptor Wall Mount Model Only 3 Owner s Manual 4 Pillow Speaker Cable Wall M...

Page 7: ...code provides guidelines for proper grounding and in particular specifies that the cable ground shall be connected to the grounding system of the building as close to the point of the cable entry as p...

Page 8: ...32 x 3 8 Phillips head machine screws Power and Signal Connections 1 Connect the ARM POWER CABLE that exits the base of the arm to the power connector on the bottom of the power supply 2 Connect the...

Page 9: ...wever the installer and architect in charge should verify current regulatory compliance CABLE SYSTEM GROUNDING The coax cable system connected to the PDI P15LCDB WR TV should be grounded in accordance...

Page 10: ...PDI P15LCDB User Manual Document Number PD196 096 Rev 2 10 Installation Exploded View Power Pack Back Mount M4 Screws 4 Wall Bracket Pilfer Screws 2...

Page 11: ...XXZ1N1 XL031E1AJ00Z1N1 XL031X0AXXXZ1N1 XL031X1AJ00Z1N1 Use type SJ cord or better for the across room wiring between the TV and the bedside pendant control A pin out is provided below WARNING DO NOT c...

Page 12: ...g the remote control Some functions can also be adjusted with the buttons on the front panel of the set POWER 1 2 3 5 4 6 7 8 9 0 MENU TV AV ST SAP SLEEP Q VIEW LIST CH CH VOL VOL OK PSM SSM PC CC Set...

Page 13: ...Radio is activated via the Setup Menu The TV AV button can be disabled using the remote control to prevent patient and visitor tampering see the Special menu and Lock instructions elsewhere in this ma...

Page 14: ...he A V IN on the TV Connection is color coded 2 Connect the video output from the device to the A V IN on the TV Connections are color coded 3 Select VIDEO mode by pressing the TV AV button repeatedly...

Page 15: ...I P15LCDB is designed to also be used as a computer monitor NOTE If mounted on a support arm the arm must be pre strung with a compatible VGA computer cable to utilize this feature 1 Connect the VGA c...

Page 16: ...080i 1920 x 1080i 31 5 Khz 31 2 Khz 45 0 Khz 37 5 Khz 33 7 Khz 28 1 Khz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz NOTE 1 If the set is cold there may be a small flicker when the set is switched ON This is n...

Page 17: ...agement Off Bed A B A Position Next Back MENU Exit TV AV Sound Equalizer Balance 0 AVL Off Surround Off Sound Mode MONO Minimum Volume 0 Maximum Volume 100 Power On Volume LAST Internal Speaker OFF Po...

Page 18: ...Power On Captions Mode Off Service Setup Position Next Back MENU Exit TV AV Position Back MENU Exit TV AV Service Level Channel Free Last Basic Last Premium Last Power On Channel Position Adjust Back...

Page 19: ...ogram 8 Press the MENU button to finish auto programming 9 Press the TV AV button to return to normal TV viewing HINTS Press the CH buttons to check the memorized channels after auto programming is fi...

Page 20: ...ed Editing of channels must be done using either Auto Program or Manual Program 1 Select the Setup menu 2 Press the CH button select Program List 3 To select a channel in on the Program List use the C...

Page 21: ...to return to the preceding Menu and the TV AV button to return to normal TV viewing BALANCE Adjusts the sound balance from the left and right speakers mounted in the TV Balance has no effect on the P...

Page 22: ...e factory default is 0 5 Press the MENU button to return to the preceding Menu and the TV AV button to return to normal TV viewing Maximum Volume Sets the maximum absolute loudness that the user could...

Page 23: ...functions to operate properly Hints Off and On times can also be set that allow the TV to turn OFF at a specified time or ON at a specified time to a specified On Program channel BLUE BACK Channels th...

Page 24: ...2 Press the CH button to select the Special menu 3 Press the CH button to select Auto Power On 4 Press the VOL button to select Auto Power On On or Off 5 Press the TV AV button to return to normal TV...

Page 25: ...button to exit and return to normal TV viewing Alternately the captions can be set using the remote control s CC button or the TV s CC control button HINTS Closed captions will only appear if the TV p...

Page 26: ...e restrictions for these two groups work independently If viewers include very young children as well as young adults the TV rating is set separately for each age group See next step 7 At this point o...

Page 27: ...word menu will appear NOTE the default password for a new TV is 0000 After entering a valid password the Parental Control menu will appear 5 Press the VOL buttons to select the MPAA Rating Then press...

Page 28: ...ge Sex and Violence Scenes Hints for Setting Parental Control Determine which rating you consider acceptable to the viewer For example if you choose TV PG all the more restrictive ratings will be auto...

Page 29: ...ervice Level 4 A listing of service levels are shown with the current settings Press the CH button to select the Service Level 5 Press the VOL button once to clear the Service Level The Service Level...

Page 30: ...ton 2 Press the CH button to select the Service Setup menu 3 Press the CH button to select Channel Lock 4 Press the VOL button to turn Chanel Lock On or Off 5 Press the TV AV button to return to norma...

Page 31: ...mory number Auto Program automates FM radio station programming Memorize 1 Press the MENU button to display the Radio Setup menu 2 Press the VOL button repeatedly to select Mode Auto or Manual tuning...

Page 32: ...ton to select the desired picture item 5 Press the VOL button to make appropriate adjustments 6 Press the TV AV button to exit menu Contrast Brightness This function adjusts the picture s brightness a...

Page 33: ...z 37 9 Khz 48 1 Khz 46 9 Khz 56 Hz 60 Hz 72 Hz 75 Hz XGA 1024x768 1024x768 1024x768 48 4 Khz 56 5 Khz 60 0 Khz 60 Hz 70 Hz 75 Hz DTV 720 x 480p 720 x 576p 1280 x 720p 1280 x 720p 1920 x 1080i 1920 x 1...

Page 34: ...pillow speaker thumbwheel volume control to maximum Adjust the VOL button on the TV to increase the volume Picture is too light Check and adjust the COLOR and CONTRAST settings Picture is too dark Ve...

Page 35: ...all shipping and freight charges to PDI s factory shall be paid by the customer This warranty shall not apply to any PDI products subjected to improper use negligence or accident nor to tampering alte...

Page 36: ...PDI P15LCDB User Manual Document Number PD196 096 Rev 2 36 Communication Systems Inc 40 Greenwood Lane Springboro Ohio 45066 USA PH 937 743 6010 FX 947 743 5664...

Reviews: