background image

 
 
 

[email protected]

 

 

 

3

 

This Operating Manual covers information on safety and cautions. Please read the
relevant information carefully and observe all the 

Warnings

 and 

Notes

 strictly.

Warning

Except where noted, the descriptions and instructions in this Operating Manual apply
to all 

Model UT61A/UT61B/UT61C/UT61D/UT61E

.

Unpacking Inspection

Open the package case and take out the Meter.  Check the following items carefully
to see any missing or damaged part:

Description

Operating Manual

Test Lead

Point Contact K type Temperature Probe (UT61B and UT61C only)

UT61 Multi-Purpose Socket

9V Battery (NEDA1604, 6F22 or 0006P) (installed inside the Meter)

RS232C Interface Cable(except UT61A)

USB Interface Cable (Optional at extra cost) (except UT61A)

Installation Guide & Computer Interface Software (CD-ROM) (Come
along with the RS232C or USB Interface Cable) (except UT61A)

Item

1

2

3

4

5

6

7

8

Qty

1 piece

1 pair

1 piece

1 piece

1 piece

1 piece

1 piece

1 piece

In the event you find any missing or damage, please contact your dealer immediately.

Safety Information

This Meter complies with the standards IEC61010: in pollution degree 2, overvoltage
category (CAT. III 1000V, CAT. IV 600V) and double insulation.

CAT III: Distribution level, fixed installation, with smaller transient overvoltages than
CAT. IV.

CAT IV: Primary supply level, overhead lines, cable systems etc.

Use the Meter only as specified in this operating manual, otherwise the protection
provided by the Meter may be impaired.

In this manual, a

 Warning

 identifies conditions and actions that pose hazards to the

user, or may damage the Meter or the equipment under test.

Note

 identifies the information that user should pay attention on.

International electrical symbols used on the Meter and in this Operating Manual are

explained on page9.

Summary of Contents for PCE-UT 61E

Page 1: ...Technical Services Ltd Unit N12B Tursdale Business Park Co Durham DH6 5PG United Kingdom Phone 44 0 191 377 3398 Fax 44 0 191 377 3357 info tursdaletechnicalservices co uk http www industrial needs c...

Page 2: ...ment G Frequency Measurement H Temperature Measurement 35 37 38 39 39 39 40 40 41 41 41 42 43 44 46 49 52 55 I Transistor hFE Measurement J EF Function Operation of Hold Mode RANGE Button MAX MIN Butt...

Page 3: ...ware CD ROM Come along with the RS232C or USB Interface Cable except UT61A Item 1 2 3 4 5 6 7 8 Qty 1 piece 1 pair 1 piece 1 piece 1 piece 1 piece 1 piece 1 piece In the event you find any missing or...

Page 4: ...hen using the test leads keep your fingers behind the finger guards l Disconnect circuit power and discharge all high voltage capacitors before testing resistance continuity and diodes l Before measur...

Page 5: ...Sensor Test UT61A only Power off OFF mV Functional Buttons Below table indicated for information about the functional button operations Press to select the maximum and minimum value Operation Perform...

Page 6: ...replace the battery as soon as the battery indicator appears Sensor test is in progress No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Symbol No The RELis on to display the stored value minus the present valu...

Page 7: ...and UT61C display effective value of sine wave mean value response UT61D and UT61E display true rms value 4 Press Hz to obtain the frequency and duty cycle value Input Amplitude DC electric level is...

Page 8: ...urement function press BLUE button 4 Connect the test lead in serial to the return circuit to be tested The measured value shows on the display UT61A UT61B and UT61C display effective value of sine wa...

Page 9: ...or AC 30V voltages To measure resistance connect the Meter as follows 1 Insert the red test lead into the terminal and the black test lead into the COM terminal 2 Set the rotary switch to resistance...

Page 10: ...the terminal and the black test lead into the COM terminal 2 Set the rotary switch to and press BLUE button to select measurement mode 3 The buzzer sounds continuously if the resistor to be tested is...

Page 11: ...readings l When diode testing has been completed disconnect the connection between the testing leads and the circuit under test and remove the testing leads away from the input terminals of the Meter...

Page 12: ...s value REL mode can help on that UT61A UT61B UT61C UT61D and UT61E around 10nF UT61E around 50PF l For more convenience use the included multi purpose socket for measuring capacitor with leads or SMT...

Page 13: ...ry switch to 2 Insert the temperature probe into the input terminal as shown on the figure 9 3 Place the temperature probe to the object being measured After few seconds the measured value shows on th...

Page 14: ...ject being measured 3 There will be three types of displays LCD displays different size of digits to represent the strength of detected signal When the LCD displays OL the buzzer beeps and the red LED...

Page 15: ...AK Hold UT61E only l Under voltage and current measurement mode press PEAK button to enter manual ranging mode and start recording of Pmax and Pmin values The LCD displays MANU Pmax l Press PEAK again...

Page 16: ...rotection for 10A Input Terminal 10A H 240V 6x25mm l Display UT61A and UT61B Maximum reading 4000 frequency 9999 analogue bar graph 41 segments UT61C and UT61D Maximum reading 6000 frequency 9999 anal...

Page 17: ...info tursdaletechnicalservices co uk 17 0 8 3 3...

Page 18: ...info tursdaletechnicalservices co uk 18 0...

Page 19: ...info tursdaletechnicalservices co uk 19 3 10...

Page 20: ...info tursdaletechnicalservices co uk 20...

Page 21: ...4 4 4 4 4 4 info tursdaletechnicalservices co uk 21 300 40 400 40M 0 01Hz 0 001Hz 0 001V 0 0001V...

Page 22: ...ibration performance test and service information To avoid electrical shock or damage to the Meter do not get water inside the case A General Service l Periodically wipe the case with a damp cloth and...

Page 23: ...leads are disconnected from the circuit being tested before opening the case bottom To replace the battery See figure 12 1 Turn the Meter power off and remove all connections from the terminals 2 Rem...

Page 24: ...emove the fuse by gently prying one end loose then take out the fuse from its bracket 5 Install ONLY replacement fuses with the identical type and specification as follows and make sure the fuse is fi...

Reviews: