Rules For Safe Operation

Warning

To avoid possible electric shock or personal injury, and to avoid possible

damage to the Meter or to the equipment under test, adhere to the following
rules:

Before using the Meter inspect the case.  Do not use the Meter if it is

      damaged or the case (or part of the case) is removed.  Look for cracks or
      missing plastic.  Pay attention to the insulation around the connectors.

Inspect the test leads for damaged insulation or exposed metal.  Check

      the test leads for continuity.  Replace damaged test leads with identical
      model number or electrical specifications before using the Meter.

Do not apply more than the rated voltage, as marked on the Meter, between

      the terminals or between any terminal and grounding.

The rotary switch should be placed in the right position and no any

      changeover of range shall be made during measurement is conducted to
      prevent damage of the Meter.

When the Meter working at an effective voltage over 60V in DC or 30V

      rms in AC, special care should be taken for there is danger of electric
      shock.

Do not use or store the Meter in an environment of high temperature,

       humidity, explosive, inflammable and strong magnetic field.  The performance
      of the Meter may deteriorate after dampened.

When using the test leads, keep your fingers behind the finger guards.

Disconnect circuit power and discharge all high-voltage capacitors before

      testing resistance, continuity and diodes.

Before measuring current, check the Meterís fuses and turn off the current

      to be tested before connecting the Meter to the circuit.  After connecting
      the circuit reliably, turn the current to be tested on.

Replace the battery as soon as the battery indicator 

 appears.  With a

      low battery, the Meter might produce false readings that can lead to electric

      

shock and personal injury.

When servicing the Meter, use only the same model number or identical

      electrical specifications replacement parts.

The internal circuit of the Meter shall not be altered at will to avoid damage

      of the Meter and any accident.

Soft cloth and mild detergent should be used to clean the surface of the

      Meter when servicing. No abrasive and solvent should be used to prevent
      the surface of the Meter from corrosion, damage and accident.

The Meter is suitable for indoor use.

Turn the Meter off when it is not in use and take out the battery when not

      using for a long time.

Constantly check the battery as it may leak when it has been using for

      some time, replace the battery as soon as leaking appears.  A leaking
      battery will damage the Meter.

International Electrical Symbols

AC or DC

Double Insulated

Warning.  Refer to the Operating
Manual

Grounding

Deficiency of Built-In Battery

Conforms to Standards of
European Union

Summary of Contents for PCE-UT 61E

Page 1: ...Technical Services Ltd Unit N12B Tursdale Business Park Co Durham DH6 5PG United Kingdom Phone 44 0 191 377 3398 Fax 44 0 191 377 3357 info tursdaletechnicalservices co uk http www industrial needs c...

Page 2: ...ment G Frequency Measurement H Temperature Measurement 35 37 38 39 39 39 40 40 41 41 41 42 43 44 46 49 52 55 I Transistor hFE Measurement J EF Function Operation of Hold Mode RANGE Button MAX MIN Butt...

Page 3: ...ware CD ROM Come along with the RS232C or USB Interface Cable except UT61A Item 1 2 3 4 5 6 7 8 Qty 1 piece 1 pair 1 piece 1 piece 1 piece 1 piece 1 piece 1 piece In the event you find any missing or...

Page 4: ...hen using the test leads keep your fingers behind the finger guards l Disconnect circuit power and discharge all high voltage capacitors before testing resistance continuity and diodes l Before measur...

Page 5: ...Sensor Test UT61A only Power off OFF mV Functional Buttons Below table indicated for information about the functional button operations Press to select the maximum and minimum value Operation Perform...

Page 6: ...replace the battery as soon as the battery indicator appears Sensor test is in progress No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Symbol No The RELis on to display the stored value minus the present valu...

Page 7: ...and UT61C display effective value of sine wave mean value response UT61D and UT61E display true rms value 4 Press Hz to obtain the frequency and duty cycle value Input Amplitude DC electric level is...

Page 8: ...urement function press BLUE button 4 Connect the test lead in serial to the return circuit to be tested The measured value shows on the display UT61A UT61B and UT61C display effective value of sine wa...

Page 9: ...or AC 30V voltages To measure resistance connect the Meter as follows 1 Insert the red test lead into the terminal and the black test lead into the COM terminal 2 Set the rotary switch to resistance...

Page 10: ...the terminal and the black test lead into the COM terminal 2 Set the rotary switch to and press BLUE button to select measurement mode 3 The buzzer sounds continuously if the resistor to be tested is...

Page 11: ...readings l When diode testing has been completed disconnect the connection between the testing leads and the circuit under test and remove the testing leads away from the input terminals of the Meter...

Page 12: ...s value REL mode can help on that UT61A UT61B UT61C UT61D and UT61E around 10nF UT61E around 50PF l For more convenience use the included multi purpose socket for measuring capacitor with leads or SMT...

Page 13: ...ry switch to 2 Insert the temperature probe into the input terminal as shown on the figure 9 3 Place the temperature probe to the object being measured After few seconds the measured value shows on th...

Page 14: ...ject being measured 3 There will be three types of displays LCD displays different size of digits to represent the strength of detected signal When the LCD displays OL the buzzer beeps and the red LED...

Page 15: ...AK Hold UT61E only l Under voltage and current measurement mode press PEAK button to enter manual ranging mode and start recording of Pmax and Pmin values The LCD displays MANU Pmax l Press PEAK again...

Page 16: ...rotection for 10A Input Terminal 10A H 240V 6x25mm l Display UT61A and UT61B Maximum reading 4000 frequency 9999 analogue bar graph 41 segments UT61C and UT61D Maximum reading 6000 frequency 9999 anal...

Page 17: ...info tursdaletechnicalservices co uk 17 0 8 3 3...

Page 18: ...info tursdaletechnicalservices co uk 18 0...

Page 19: ...info tursdaletechnicalservices co uk 19 3 10...

Page 20: ...info tursdaletechnicalservices co uk 20...

Page 21: ...4 4 4 4 4 4 info tursdaletechnicalservices co uk 21 300 40 400 40M 0 01Hz 0 001Hz 0 001V 0 0001V...

Page 22: ...ibration performance test and service information To avoid electrical shock or damage to the Meter do not get water inside the case A General Service l Periodically wipe the case with a damp cloth and...

Page 23: ...leads are disconnected from the circuit being tested before opening the case bottom To replace the battery See figure 12 1 Turn the Meter power off and remove all connections from the terminals 2 Rem...

Page 24: ...emove the fuse by gently prying one end loose then take out the fuse from its bracket 5 Install ONLY replacement fuses with the identical type and specification as follows and make sure the fuse is fi...

Reviews: