56
SAFIR 5L
OPERATION AND ATTENDANCE MANUAL
PG 01-31
APU is running for 2 sec. only
Perform the checks error messages the EC via PC, RS232
interface on a COM port and software "SAFIR Monitor"
Error messages the EC –
Speed signal failure
Little or no signal level of APU speed
Board network voltage in order
Check the
feeding
Cables between the pickuk of revolutions and
the Control Box in order
When checking the Control Box by
means of simulator is function normal
Repair cables
TEST
Replace
Control Box
NO
NO YES
Distance between the Speed
Transmitter TP and the tooth whel
is correct
NO
YES
YES
YES NO
Replace
Control Box
Adjust prescribed
distanc:
0,15÷0,3 mm