27
5 - INSTALLATION - Mounting & gas and water connections
WARNING!!! If the combustion
levels are not within the range given
in Table 3 for the fi ring rate, shut
the boiler down and contact your
distributor or the boiler manufacturer
(see reference in the last cover
page). Failure to comply with this
requirement could result in severe
personal injury, death or substantial
property damage.
15 - Attach to the front of the boiler
the appropriate conversion label,
found in the conversion kit (see
Figure 14 or Figure 15), stating the
new type of gas adjustment of the
boiler.
a - Apply the label in Figure 15 if the
boiler has been converted to
LP
GAS
;
b - Apply the label in Figure 14 if
the boiler has been converted to
NATURAL GAS
.
Figure 14 - Label for Natural gas boiler
Figure 13 - Gas valve
Figure 15 - Label for LP gas boiler
ATTENTION!!!
This heater has been converted for use with
NATURAL GAS
- Maximum inlet gas pressure: 13 In.W.C.
- Minimum inlet gas pressure: 3 In.W.C.
- Manifold pressure: (see rating plate)
- Input rating: (see rating plate)
This water heater was converted on (day-month-year)
___________________to ___________________ gas
with kit nº___________________________________
by_________________________________________
___________________________________________
(name and address of organization making this
conversion, who accepts the responsibility for the
correctness of this conversion).
ATTENTION!!!
This heater has been converted for use with
LP GAS
- Maximum inlet gas pressure: 13 In.W.C.
- Minimum inlet gas pressure: 3 In.W.C.
- Manifold pressure: (see rating plate)
- Input rating: (see rating plate)
This water heater was converted on (day-month-year)
___________________to ___________________ gas
with kit nº___________________________________
by_________________________________________
___________________________________________
(name and address of organization making this
conversion, who accepts the responsibility for the
correctness of this conversion).
Summary of Contents for Peerless Combi 160
Page 3: ...3 SAFETY INSTRUCTIONS...
Page 97: ...97 13 MAINTENANCE...
Page 105: ...105 NOTES...