EN – Installer information
User and installation instructions
Connection of 100–240 V AC
and 12 V DC must not be done
simultaneously (Figure M).
NB. Maximum variation for 12 V DC
voltage of 10 - 13.6 V DC.
NB. For 12VDC always use switches
intended for direct current, C.
M.
N.
No 100–240 V cables may
be laid over the electronics
component (Figure N).
Norte auto:
12 V DC (switch C always on)
Factory-set for continuous basic ventilation, auto-
matic forcing at elevated humidity levels and under
the influence of changes in light.
Norte switch-operated on/off:
(Can be combined with backdraught shutter)
12 V DC
Must be selected via Pax App.
Start/stop via manual switch C.
Norte humidity-controlled:
(Can be combined with backdraught shutter)
12 V DC (switch C always on)
Must be selected via Pax App.
Basic setting, automatic start/stop at changes in
humidity level.
Norte heat distributor:
12 V DC (switch C always on)
Must be selected via Pax App.
Basic setting, starts at 25 °C, stops at 22 °C.
ELECTRICAL CONNECTION 12 V DC
NB. Pax recommends that electrical connection of
12 V DC be performed by a qualified electrician.
Electrical
connection
12 V DC