System Log—Modify
252
Model 1001MC Operations Guide
10 • HTTP/HTML web page reference
Figure 122. System Log—Modify
System Log—Modify
The
System Log—Modify
page (see
figure 122
) allows you to modify the system log parameters. You can
choose which messages will be sent to the available message logging functions.
Daemons
Syslog Daemon IP Address (syslogDaemonIP)
The Model 1001MC can send messages over a network to a Syslog Daemon. This variable specifies the IP address
that will be running the Syslog Daemon. Type the IP address into the text box, then click the
Submit
button.
Note
After submitting the change, you must click on the
Record Current
Con
fi
guration
button located on the
HOME
page to store the config-
uration changes into memory (see
“HOME”
on page 228 for more
information).