Using a Web browser to complete DACS configuration
43
Model 2604 E1/T1 DACS Getting Started Guide
3 • Configuring the DACS for operation
Figure 25. T1/E1 Link Activity window
Configuring line settings and signaling for E1
1. Select
T1/E1 Link
on the
Configuration Menu
. The T1/E1 Link Activity window appears (see figure 25).
2.
Link: 1
corresponds to Line 1 on the DACS. Under Link 1, Click on
Configuration
then
Modify
. The Line
Interface Settings section of the WAN Circuit Configuration window appears (see figure 26).
Figure 26. WAN Circuit Configuration window, Line Interface Settings section
Configuring the line settings
1. Click on the
Line Type
pop-up menu (see figure 26 on page 43) and choose either dsx1EX(4) or dsx1E1-
CRC(5).
2. Click on the
Line Coding
pop-up menu (see figure 26 on page 43) and choose either dsx1AMI(5) or
dsxHDB3(3). Most installations will use HDB3.