Configuring Card System Clocking
34
FS6300 NMS Getting Started Guide
3 • Configuring Alarms and Clocking
Refreshing the alarms after configuring clocking
After you have configured clocking for the chassis, you can refresh the alarms that occurred before clocking was
configured. To refresh the alarms for a card:
1.
Right-click on the card icon and select
Alarm Parameter Configuration
.
The
FS6300 Alarm Details
window displays (see
Figure 10
on page 30).
2.
Click on
Alarm System Overview
in the menu tree on the left side of the screen.
3.
Click the
Clear All Alarms
button.
4.
Click the
Refresh
button.
All of the alarms that were related to clocking should be cleared. (Other alarms not related to clocking may still
be present). The next step after configuring clocking synchronization is to configure clocking options for the
card system, including Clock Fallback and Clock Auto Recover.
Configuring Card System Clocking
In addition to setting a clock to Master, Secondary, or Slave, you must also select the source for clocking and
determine whether to enable or disable Clock Fallback and Clock Auto Recover. To configure card system
clocking:
1.
Right-click on the card icon and select
Card System Clocking
.
Figure 15. Card Menu > Card System Clocking
The
System Clocking
window displays.