Administering user accounts
125
Model 3201 G.SHDSL Integrated Access Device User Guide
D • Command Line Interface (CLI) Operation
3. The interface type needs to be the same to pass data (Interface)
4. Issue the ‘Action’ command to start the handshaking process (Action Start)
Example: To set up the units to run at 2.048Mbps using ATM interface.
For CO (central) unit
→
gshdsl set terminal central
→
gshdsl set interface utopia
→
gshdsl set dataRateN 32
→
gshdsl set dataRateI 0
→
gshdsl set Action Start
For CPE (remote) unit
→
gshdsl set terminal remote
→
gshdsl set interface utopia
→
gshdsl set dataRateN 32
→
gshdsl set dataRateI 0
→
gshdsl set Action Start
Default Setting of the unit
Terminal:
Remote
Interface:
Hdlc
DataRateN:
24
DataRateI:
0