Switches S1-1:  Test Mode Activation

Use Switch S1-1 to enable or disable the Model 2070/Dx Test

Mode.  When enabled, the Local Line and G.703 loopback tests are
activated simultaneously.  When disabled, the Model 2070/Dx functions
normally.

S1-1

Activation

Description

On

Enabled

Local Loop and G.703 Loop
diagnostics enabled

Off

Disabled

Local Loop and G.703 Loop
diagnostics disabled

Switch S1-2 :  Clocking Mode

Use Switch S1-2  to set the system clock for the Model 2070/Dx.

When using two Model 2070s together in a point-to-point application as
short range modems, set one unit  for Internal clock and the other unit
to Network clock. When connecting directly to the G.703 network, set
the unit to Network clock.

S1-2

Clocking

Description

On

Network

The G.703 network 
provides the system clock

Off

Internal

The Model 2070/Dx provides 
an internally generated 
system clock

15

MODEL 2070/Dx SWITCH S1 SUMMARY TABLE

Position

Function

Factory Default

S1-1

Test Mode

Off

Disabled

S1-2

Clock Mode

On

Network

S1-3

Byte Timing

On

Enabled

S1-4

Reserved

Off

Switch S1-3:  Byte Timing

Use Switch S1-3 to enable byte timing on the Model 2040/Dx.  The

Byte timing clock is an 8 KHz (1 byte/sync. pulse) framing clock
synchronized to the G.703 Data.

S1-3

Activation

Description

On

Enabled 

Model 2070/Dx outputs Byte Timing

Off

Disabled

Byte timing is disabled

Switch S1-4:  Reserved for Factory Use

Switch S1-4 is reserved for factory use and must remain in the

Off position.

S1-4

Activation

On

Not a Valid Setting

Off

Normal Operation

3.4.2  Jumper Strap “JP1” and “JP2”

The Model 2070/Dx uses two jumper straps (JP1 and JP2, see

Figure 13 below) to select the power source option and to connect the
unit signal ground  to frame ground. 

.

Figure 14 (following page) shows possible settings of jumper straps

JP1 and JP2.   JP1 may be positioned on  pegs 1 and 2 or  on pegs 1
and 3; JP2 may be positioned on pegs 4 and 6 or on pegs 5 and 6. A
detailed description of each jumper strap follows Figure 14.

16

Figure 13. Location of Strap JP1 and JP2 on the top of the Model 2070/Dx PC board

Jumpers JP1 & JP2

1
3
5

2
4
6

Summary of Contents for 2070 Series

Page 1: ...es V 24 X 21 V 35 to G 703 Interface Converter SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2070 UM Doc 03106U2 001 Rev D Revised 10 25 06 C E R T I F I E D An...

Page 2: ...inability to use this product Patton Electronics specifically disclaims all other warranties expressed or implied and the installation or use of this product shall be deemed an acceptance of these te...

Page 3: ...stomer Service at 301 975 1007 2 1 FEATURES Bi directionally converts V 24 X 21 or V 35 to co directional G 703 Operates at 64 kbps synchronous data rate LED indicators monitor Test Mode and Synchroni...

Page 4: ...ircuits which may carry dangerous voltages Therefore the power and network cables must be disconnected prior to switch and jumper configuration 3 2 CONFIGURATION MODEL 2070 Ax V 24 VERSION The Model 2...

Page 5: ...ction Factory Default S1 1 Test Mode Off Disabled S1 2 Clock Mode On S1 3 Clock Mode On S1 4 Respond to LL Request On Disabled Network Clock 8 Switch S1 4 Response to DTE Request for Local Loopback Us...

Page 6: ...P1 Power Source 1 3 AC Powered JP2 SGND to FGND 5 6 Connected 3 3 CONFIGURATION MODEL 2070 Cx V 35 VERSION The Model 2070 Cx uses a mini DIP switch package and a jumper strap that allow configuration...

Page 7: ...11 MODEL 2070 Cx SWITCH S1 SUMMARY TABLE Position Function Factory Default S1 1 Test Mode Off Disabled S1 2 Clock Mode On S1 3 Clock Mode On S1 4 Response to LL Request On Disabled Network Clock Switc...

Page 8: ...efault JP1 Power Source 1 3 AC Powered JP2 SGND to FGND 5 6 Connected 3 4 CONFIGURATION MODEL 2070 Dx X 21 VERSION The Model 2070 Dx uses a mini DIP switch package and a jumper strap that allow config...

Page 9: ...fault S1 1 Test Mode Off Disabled S1 2 Clock Mode On Network S1 3 Byte Timing On Enabled S1 4 Reserved Off Switch S1 3 Byte Timing Use Switch S1 3 to enable byte timing on the Model 2040 Dx The Byte t...

Page 10: ...P2 JP1 4 0 INSTALLATION The Model 2070 is designed for 4 wire full duplex communication over a co directional 64 kbps G 703 clear channel network or dedicated twisted pair This section describes the p...

Page 11: ...n com or http www patton com for specific interface pin assignments 4 4 POWER CONNECTION The 120VAC U S wall transformer version supplies 5V regulated DC up to 300mA The variable 110 230VAC internatio...

Page 12: ...following page 21 TM SYNC Power Jack RJ45 Jack Figure 15 Model 2070 back panel LED indicators 22 G 703 Loop The G 703 Loop test allows the G 703 service provider to test the condition of the twisted...

Page 13: ...o 95 noncondensing Dimensions Model 2070 Ax 2 9 x 1 4 x 0 7 7 4 x 3 6 x 1 8 cm Model 2070 Cx 3 9 x 1 4 x 7 10 0 x 3 6 x 1 8 cm Model 2070 Dx 2 6 x 1 4 x 0 7 6 7 x 3 6 x 1 8 cm 23 APPENDIX B PATTON MOD...

Page 14: ...tzerland Power Cord 07M2070 User Manual 25 APPENDIX D PATTON MODEL 2070 INTERFACE PIN ASSIGNMENTS G 703 INTERFACE The G 703 Interface is an RJ 45 modular jack Pin Signal 1 RX Line Receive Positive 2 R...

Page 15: ...INDICATION A 6 SIGNAL TIMING A 7 8 SIGNAL GROUND TRANSMIT B 9 CONTROL B 10 RECEIVE B 11 INDICATION B 12 14 15 SIGNAL TIMING 12 1 Frame Ground 2 Transmit A 3 Control A 4 Receive A 5 Indication A 6 Sign...

Page 16: ......

Reviews: