Jumper JP1:  Power Source

The Model 2070/Ax may be powered by the RS-232 interface or by

the supplied AC wall-mount transformer.  The setting for JP1
determines how the Model 2070/Ax receives its operating power.

JP1

Position 1&2

Interface Power Option.  In this setting the 
2070/Ax  is powered from the DTE 
interface.  Power should be applied to DB-25 
pin 9 at +5VDC (±5%), 300mA (min). The AC 
wall-mount transformer must not be 
connected in this setting.

Position 1&3

AC Power Option.  In this setting, the 2070/Ax 

is powered by the AC wall mount transformer 

Jumper JP2:  SGND & FRGND 

In the default position, Signal Ground is connected to Frame

Ground.  In the disconnected position, this strap disconnects Signal
Ground and Frame Ground.  

Position 4&6

G.703 FRGND connected to DTE FRGND.  
Both are disconnected from SGND

.

Position 5&6  

G.703 FRGND connected to DTE FRGND
Both are connected to SGND 

(default).

9

2070/Ax JP1 AND JP2 SUMMARY TABLE

Position

Function

Factory Default

JP1

Power Source

1&3 AC Powered

JP2

SGND to FGND

5&6 Connected

3.3  CONFIGURATION  (MODEL 2070/Cx -- V.35 VERSION)

The Model 2070/Cx uses a mini DIP switch package and a jumper

strap that allow configuration to a wide range of applications.  The
switch is located on the bottom side and the jumper strap is located on
the top side of the PC board.  Follow the instructions below to configure
the 2070/Cx (V35 Version).  See Section 3.2 to configure the Model
2070/Ax (V.24 Version) or Section 3.4 to configure the Model
2070/Dx (X.21 Version).

3.3.1  Configuration Switch Set “S1”

The four switches on DIP Switch S1 are used to select the test

mode and clock mode functions.  Figure 7 shows the position of Switch
S1 on the bottom side of the Model 2070/Cx.

Figure 8 shows the orientation of the Switches on DIP Switch S1

with respect to ON/OFF positions.  The default settings for DIP switch
S1 are shown in the table on the following page.  Detailed descriptions
of each switch follow the table. 

10

Figure 8. Close-up of DIP Switches Showing “ON” and “OFF” Positions

ON

1 2 3 4

OFF

ON

Figure 7. Location of Switch S1 on the bottom of the 2070/Cx PC board

ON

1 2 3 4

Switch S1

1234

Summary of Contents for 2070 Series

Page 1: ...es V 24 X 21 V 35 to G 703 Interface Converter SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2070 UM Doc 03106U2 001 Rev D Revised 10 25 06 C E R T I F I E D An...

Page 2: ...inability to use this product Patton Electronics specifically disclaims all other warranties expressed or implied and the installation or use of this product shall be deemed an acceptance of these te...

Page 3: ...stomer Service at 301 975 1007 2 1 FEATURES Bi directionally converts V 24 X 21 or V 35 to co directional G 703 Operates at 64 kbps synchronous data rate LED indicators monitor Test Mode and Synchroni...

Page 4: ...ircuits which may carry dangerous voltages Therefore the power and network cables must be disconnected prior to switch and jumper configuration 3 2 CONFIGURATION MODEL 2070 Ax V 24 VERSION The Model 2...

Page 5: ...ction Factory Default S1 1 Test Mode Off Disabled S1 2 Clock Mode On S1 3 Clock Mode On S1 4 Respond to LL Request On Disabled Network Clock 8 Switch S1 4 Response to DTE Request for Local Loopback Us...

Page 6: ...P1 Power Source 1 3 AC Powered JP2 SGND to FGND 5 6 Connected 3 3 CONFIGURATION MODEL 2070 Cx V 35 VERSION The Model 2070 Cx uses a mini DIP switch package and a jumper strap that allow configuration...

Page 7: ...11 MODEL 2070 Cx SWITCH S1 SUMMARY TABLE Position Function Factory Default S1 1 Test Mode Off Disabled S1 2 Clock Mode On S1 3 Clock Mode On S1 4 Response to LL Request On Disabled Network Clock Switc...

Page 8: ...efault JP1 Power Source 1 3 AC Powered JP2 SGND to FGND 5 6 Connected 3 4 CONFIGURATION MODEL 2070 Dx X 21 VERSION The Model 2070 Dx uses a mini DIP switch package and a jumper strap that allow config...

Page 9: ...fault S1 1 Test Mode Off Disabled S1 2 Clock Mode On Network S1 3 Byte Timing On Enabled S1 4 Reserved Off Switch S1 3 Byte Timing Use Switch S1 3 to enable byte timing on the Model 2040 Dx The Byte t...

Page 10: ...P2 JP1 4 0 INSTALLATION The Model 2070 is designed for 4 wire full duplex communication over a co directional 64 kbps G 703 clear channel network or dedicated twisted pair This section describes the p...

Page 11: ...n com or http www patton com for specific interface pin assignments 4 4 POWER CONNECTION The 120VAC U S wall transformer version supplies 5V regulated DC up to 300mA The variable 110 230VAC internatio...

Page 12: ...following page 21 TM SYNC Power Jack RJ45 Jack Figure 15 Model 2070 back panel LED indicators 22 G 703 Loop The G 703 Loop test allows the G 703 service provider to test the condition of the twisted...

Page 13: ...o 95 noncondensing Dimensions Model 2070 Ax 2 9 x 1 4 x 0 7 7 4 x 3 6 x 1 8 cm Model 2070 Cx 3 9 x 1 4 x 7 10 0 x 3 6 x 1 8 cm Model 2070 Dx 2 6 x 1 4 x 0 7 6 7 x 3 6 x 1 8 cm 23 APPENDIX B PATTON MOD...

Page 14: ...tzerland Power Cord 07M2070 User Manual 25 APPENDIX D PATTON MODEL 2070 INTERFACE PIN ASSIGNMENTS G 703 INTERFACE The G 703 Interface is an RJ 45 modular jack Pin Signal 1 RX Line Receive Positive 2 R...

Page 15: ...INDICATION A 6 SIGNAL TIMING A 7 8 SIGNAL GROUND TRANSMIT B 9 CONTROL B 10 RECEIVE B 11 INDICATION B 12 14 15 SIGNAL TIMING 12 1 Frame Ground 2 Transmit A 3 Control A 4 Receive A 5 Indication A 6 Sign...

Page 16: ......

Reviews: