background image

Jumper JP1:  Power Source

The Model 2070/Dx may be powered by the X.21 interface or by

the supplied AC wall-mount transformer.  The setting for JP1
determines how the Model 2070/Dx receives its operating power.

JP1

Position 1&2

Interface Power Option.  In this setting the 
2070/Dx  is powered from the DTE 
interface.  Power should be applied to DB-15 
pin 15 at +5VDC (±5%), 300mA (min) The AC
wall-mount transformer must not be 
connected in this setting.

Position 1&3

AC Power Option.  In this setting, the 2070/Dx

is powered by the AC wall mount transformer 

Jumper JP2:  SGND & FRGND 

In the default position, Signal Ground is connected to Frame

Ground.  In the disconnected position, this strap disconnects Signal
Ground and Frame Ground.  

Position 4&6

G.703 FRGND connected to DTE FRGND.  
Both are disconnected from SGND

.

Position 5&6  

G.703 FRGND connected to DTE FRGND
Both are connected to SGND 

17

2070/Dx JP1 AND JP2 SUMMARY TABLE

Position

Function

Factory Default

JP1

Power Source

1&3 AC Powered

JP2

SGND to FGND

5&6 Connected

Figure 14. Possible Settings of Jumper Straps JP1 and JP2

1

2

3

4

5

6

JP2

JP1

4.0  INSTALLATION

The Model 2070 is designed for 4-wire, full duplex communication

over a co-directional 64 kbps G.703 clear channel network or dedicated
twisted pair.  This section describes the proper connection of the line
interface, the DTE (terminal) interface, and AC/DC power.

4.1  CONNECTING TO A PCM NETWORK CHANNEL

The RJ-45 port on a Model 2070  is pre-wired for direct connection

to the G.703 PCM  network.  Connect the RJ-45 port of the Model 2070
to the RJ-45 jack provided by your digital service carrier using a
straight through twisted pair cable between 19 and 26 AWG.   To be
sure you have the right wiring, use the diagram below as a guide.

4.2  CONNECTING OVER PRIVATE TWISTED PAIR

If you wish to connect the Model 2070 to another Model 2070 (or

compatible G.703 device) over private twisted pair,  make the
connection between the two devices using a crossover cable pinned
according to the diagram below.

RJ-45 Cable (8-Wire)

SIGNAL

PIN#

PIN#

SIGNAL

RX+

1-----------------------5

TX+

RX-

2-----------------------4

TX-

TX+

5-----------------------1

RX+

TX-

4-----------------------2

RX

Shield

3-----------------------3

Shield

Shield

6-----------------------6

Shield

18

1 (RX+)
2 (RX-)
3 (N/C)
4 (TX-)
5 (TX+)
6 (N/C)
7 (N/C)
8 (N/C)








Notice!

The G.703 line surge protection on this unit was

installed for circuit protection only.  By no means does this
include the preservation of signal quality during a large surge. 

Summary of Contents for 2070 Series

Page 1: ...es V 24 X 21 V 35 to G 703 Interface Converter SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2070 UM Doc 03106U2 001 Rev D Revised 10 25 06 C E R T I F I E D An...

Page 2: ...inability to use this product Patton Electronics specifically disclaims all other warranties expressed or implied and the installation or use of this product shall be deemed an acceptance of these te...

Page 3: ...stomer Service at 301 975 1007 2 1 FEATURES Bi directionally converts V 24 X 21 or V 35 to co directional G 703 Operates at 64 kbps synchronous data rate LED indicators monitor Test Mode and Synchroni...

Page 4: ...ircuits which may carry dangerous voltages Therefore the power and network cables must be disconnected prior to switch and jumper configuration 3 2 CONFIGURATION MODEL 2070 Ax V 24 VERSION The Model 2...

Page 5: ...ction Factory Default S1 1 Test Mode Off Disabled S1 2 Clock Mode On S1 3 Clock Mode On S1 4 Respond to LL Request On Disabled Network Clock 8 Switch S1 4 Response to DTE Request for Local Loopback Us...

Page 6: ...P1 Power Source 1 3 AC Powered JP2 SGND to FGND 5 6 Connected 3 3 CONFIGURATION MODEL 2070 Cx V 35 VERSION The Model 2070 Cx uses a mini DIP switch package and a jumper strap that allow configuration...

Page 7: ...11 MODEL 2070 Cx SWITCH S1 SUMMARY TABLE Position Function Factory Default S1 1 Test Mode Off Disabled S1 2 Clock Mode On S1 3 Clock Mode On S1 4 Response to LL Request On Disabled Network Clock Switc...

Page 8: ...efault JP1 Power Source 1 3 AC Powered JP2 SGND to FGND 5 6 Connected 3 4 CONFIGURATION MODEL 2070 Dx X 21 VERSION The Model 2070 Dx uses a mini DIP switch package and a jumper strap that allow config...

Page 9: ...fault S1 1 Test Mode Off Disabled S1 2 Clock Mode On Network S1 3 Byte Timing On Enabled S1 4 Reserved Off Switch S1 3 Byte Timing Use Switch S1 3 to enable byte timing on the Model 2040 Dx The Byte t...

Page 10: ...P2 JP1 4 0 INSTALLATION The Model 2070 is designed for 4 wire full duplex communication over a co directional 64 kbps G 703 clear channel network or dedicated twisted pair This section describes the p...

Page 11: ...n com or http www patton com for specific interface pin assignments 4 4 POWER CONNECTION The 120VAC U S wall transformer version supplies 5V regulated DC up to 300mA The variable 110 230VAC internatio...

Page 12: ...following page 21 TM SYNC Power Jack RJ45 Jack Figure 15 Model 2070 back panel LED indicators 22 G 703 Loop The G 703 Loop test allows the G 703 service provider to test the condition of the twisted...

Page 13: ...o 95 noncondensing Dimensions Model 2070 Ax 2 9 x 1 4 x 0 7 7 4 x 3 6 x 1 8 cm Model 2070 Cx 3 9 x 1 4 x 7 10 0 x 3 6 x 1 8 cm Model 2070 Dx 2 6 x 1 4 x 0 7 6 7 x 3 6 x 1 8 cm 23 APPENDIX B PATTON MOD...

Page 14: ...tzerland Power Cord 07M2070 User Manual 25 APPENDIX D PATTON MODEL 2070 INTERFACE PIN ASSIGNMENTS G 703 INTERFACE The G 703 Interface is an RJ 45 modular jack Pin Signal 1 RX Line Receive Positive 2 R...

Page 15: ...INDICATION A 6 SIGNAL TIMING A 7 8 SIGNAL GROUND TRANSMIT B 9 CONTROL B 10 RECEIVE B 11 INDICATION B 12 14 15 SIGNAL TIMING 12 1 Frame Ground 2 Transmit A 3 Control A 4 Receive A 5 Indication A 6 Sign...

Page 16: ......

Reviews: