Switches S1-1:  Test Mode Activation

Use Switch S1-1 to enable or disable the Model 2070/Ax Test

Mode.  When enabled, the Local Line and G.703 loopback tests
activate simultaneously.  When disabled, the Model 2070/Ax functions
normally.

S1-1

Activation

Description

On

Enabled

Local Loop and G.703 Loop 
diagnostics enabled

Off

Disabled

Local Loop and G.703 Loop 
diagnostics disabled

Switches S1-2 and S1-3:  Clocking Mode

Use Switches S1-2 and S1-3  together to set the system clock for

the Model 2070/Ax.  When using two Model 2070s together in a point-
to-point application as short range modems, set one unit  for either
Internal or External transmit clock and the other unit to Network clock.
When connecting directly to the G.703 network, set the unit to Network
clock.

S1-2

S1-3

Clocking

Description

On

On

Network

The G.703 network 
provides the system clock

On

Off

External

The DTE provides the 
system clock

Off

On

Internal

The Model 2070/Ax 
provides an internally 
generated system clock

7

2070/Ax SWITCH S1 SUMMARY TABLE

Position

Function

Factory Default

S1-1

Test Mode

Off

Disabled

S1-2

Clock Mode

On

S1-3

Clock Mode

On

S1-4

Respond to LL Request

On

Disabled

}

Network

Clock

8

Switch S1-4:  Response to DTE Request for Local Loopback

Use Switch S1-4 to enable the Model 2070/Ax to enter Local

Loopback mode when pin 18 from the V.24 interface is raised.  In the
On position, the Local Loopback may only be enabled manually by
Switch S1-1.

S1-4

Activation

Description

On

Disabled 

Model 2070/Ax  ignores DTE 
requests to enter Local Loopback

Off

Enabled

Model 2070/Ax enters Local 
Loopback Mode when pin 18 is 
raised

3.2.2  Jumper Straps “JP1” and “JP2”

The Model 2070/Ax uses two jumper straps to select the power

source option and to connect the unit signal ground  to frame ground.
Figure 5 (below)  shows the position of Jumper Straps JP1 and JP2 on
the bottom side of the Model 2070/Ax PC board.

Figure 6  shows possible settings of jumper straps JP1 and JP2.

JP1 may be positioned on  pegs 1 and 2 or  on pegs 1 and 3; JP2 may
be positioned on pegs 4 and 6 or on pegs 5 and 6.  

ON

1

2

3

4

Figure 5. Location of Strap JP1 and JP2 on the bottom of the Model 2070/Ax PC board

Figure 6. Possible Settings of Jumper Straps JP1 and JP2

1
3
5

2
4
6

Jumpers JP1

& JP2

1

2

3

5

6

JP2

JP1

4

Summary of Contents for 2070 Series

Page 1: ...es V 24 X 21 V 35 to G 703 Interface Converter SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2070 UM Doc 03106U2 001 Rev D Revised 10 25 06 C E R T I F I E D An...

Page 2: ...inability to use this product Patton Electronics specifically disclaims all other warranties expressed or implied and the installation or use of this product shall be deemed an acceptance of these te...

Page 3: ...stomer Service at 301 975 1007 2 1 FEATURES Bi directionally converts V 24 X 21 or V 35 to co directional G 703 Operates at 64 kbps synchronous data rate LED indicators monitor Test Mode and Synchroni...

Page 4: ...ircuits which may carry dangerous voltages Therefore the power and network cables must be disconnected prior to switch and jumper configuration 3 2 CONFIGURATION MODEL 2070 Ax V 24 VERSION The Model 2...

Page 5: ...ction Factory Default S1 1 Test Mode Off Disabled S1 2 Clock Mode On S1 3 Clock Mode On S1 4 Respond to LL Request On Disabled Network Clock 8 Switch S1 4 Response to DTE Request for Local Loopback Us...

Page 6: ...P1 Power Source 1 3 AC Powered JP2 SGND to FGND 5 6 Connected 3 3 CONFIGURATION MODEL 2070 Cx V 35 VERSION The Model 2070 Cx uses a mini DIP switch package and a jumper strap that allow configuration...

Page 7: ...11 MODEL 2070 Cx SWITCH S1 SUMMARY TABLE Position Function Factory Default S1 1 Test Mode Off Disabled S1 2 Clock Mode On S1 3 Clock Mode On S1 4 Response to LL Request On Disabled Network Clock Switc...

Page 8: ...efault JP1 Power Source 1 3 AC Powered JP2 SGND to FGND 5 6 Connected 3 4 CONFIGURATION MODEL 2070 Dx X 21 VERSION The Model 2070 Dx uses a mini DIP switch package and a jumper strap that allow config...

Page 9: ...fault S1 1 Test Mode Off Disabled S1 2 Clock Mode On Network S1 3 Byte Timing On Enabled S1 4 Reserved Off Switch S1 3 Byte Timing Use Switch S1 3 to enable byte timing on the Model 2040 Dx The Byte t...

Page 10: ...P2 JP1 4 0 INSTALLATION The Model 2070 is designed for 4 wire full duplex communication over a co directional 64 kbps G 703 clear channel network or dedicated twisted pair This section describes the p...

Page 11: ...n com or http www patton com for specific interface pin assignments 4 4 POWER CONNECTION The 120VAC U S wall transformer version supplies 5V regulated DC up to 300mA The variable 110 230VAC internatio...

Page 12: ...following page 21 TM SYNC Power Jack RJ45 Jack Figure 15 Model 2070 back panel LED indicators 22 G 703 Loop The G 703 Loop test allows the G 703 service provider to test the condition of the twisted...

Page 13: ...o 95 noncondensing Dimensions Model 2070 Ax 2 9 x 1 4 x 0 7 7 4 x 3 6 x 1 8 cm Model 2070 Cx 3 9 x 1 4 x 7 10 0 x 3 6 x 1 8 cm Model 2070 Dx 2 6 x 1 4 x 0 7 6 7 x 3 6 x 1 8 cm 23 APPENDIX B PATTON MOD...

Page 14: ...tzerland Power Cord 07M2070 User Manual 25 APPENDIX D PATTON MODEL 2070 INTERFACE PIN ASSIGNMENTS G 703 INTERFACE The G 703 Interface is an RJ 45 modular jack Pin Signal 1 RX Line Receive Positive 2 R...

Page 15: ...INDICATION A 6 SIGNAL TIMING A 7 8 SIGNAL GROUND TRANSMIT B 9 CONTROL B 10 RECEIVE B 11 INDICATION B 12 14 15 SIGNAL TIMING 12 1 Frame Ground 2 Transmit A 3 Control A 4 Receive A 5 Indication A 6 Sign...

Page 16: ......

Reviews: