ADMIN/SECURITY
This menu contains settings and sub-menus pertaining to rebooting or factory defaulting the device, creating or recalling
device restore points, or generating or resetting security settings.
Admin/Security
Generate Local Security
Factory Default
Manage Restore Point
Reset Security
Reboot
<Back>
Menu Item
Description
Generate Local Security
Will appear only when device is not secured,
e.g. when powered on for the first
time, or after being factory defaulted or after having security settings reset.
Selecting this will generate local security for the device. You will be able configure
the device using the front panel
only
; you will
not
be able to change settings using
Pathscape.
Additionally, some functionality will be
unavailable
(i.e. Pathway ssACN and Custom
Patches).
To enable Pathway ssACN and configuration using Pathscape, the device must be
added to a Security Domain.
If already Locally Secured, you must factory default the device or reset its security
settings, then use Pathscape to add it to a Security Domain.
See the Security section earlier in the manual for detailed instructions.
Once the device is secured (whether by Local Security or a Security Domain) this menu
item will not be shown.
Factory Default
Allows you to restore the device to its factory settings, with a few options.
You may choose to:
Keep Net Setup & Restore Pt.
: Resets all device settings except current network
settings and any saved restore point.
Keep Restore Point
: Resets all device settings, including network settings, but
keeps any saved restore point.
Wipe All Configuration
: Resets all device settings, including all network settings,
security settings and deletes any restore point.
For each option, you will have to confirm your decision to factory default the device.
<Back>: Return to previous menu without resetting the device.