All-in-one solar charge inverter V11 30
4.3 Battery type parameters
For Lead-acid Battery :
Battery type
Parameters
Sealed lead
acid battery
(SLD)
Colloidal lead
acid battery
(GEL)
Vented lead
acid battery
(FLD)
User-defined
(User)
Overvoltage disconnection
voltage
60V
60V
60V
40~60V
(Adjustable)
Battery fully charged
recovery point
(setup item
37)
52V
(Adjustable)
52V
(Adjustable)
52V
(Adjustable)
52V
(Adjustable)
Equalizing charge voltage
58.4V
56.8V
59.2V
40~60V
(Adjustable)
Boost charge voltage
57.6V
56.8V
58.4V
40~60V
(Adjustable)
Floating charge voltage
55.2V
55.2V
55.2V
40~60V
(Adjustable)
Undervoltage alarm
voltage(01 fault)
44V
44V
44V
40~60V
(Adjustable)
Undervoltage alarm
voltage
recovery point
(01
fault)
Undervoltage alarm 0.8V
Low voltage disconnection
voltage(04 fault)
42V
42V
42V
40~60V
(Adjustable)
Low voltage disconnection
voltage recovery point
(04
fault)(setup item 35)
52V
(Adjustable)
52V
(Adjustable)
52V
(Adjustable)
52V
(Adjustable)
Discharge limit voltage
40V
40V
40V
40~60V
(Adjustable)
Over-discharge delay time
5s
5s
5s
1~30s
(Adjustable)
Equalizing charge duration
120
minutes
-
120
minutes
0~600
minutes
(Adjustable)
Equalizing charge interval
30
days
-
30
days
0~250
days
(Adjustable)
Boost charge duration
120
minutes
120
minutes
120
minutes
10~600
minutes
(Adjustable)