All-in-one solar charge inverter V11 34
9
Overload
protection
Output again 3 minutes after an overload protection, and turn the
output off after 5 consecutive times of overload protection until the
machine is re-powered. For the specific overload level and duration,
refer to the technical parameters table in the manual.
10
PV reverse polarity
protection
When the PV polarity is reversed, the machine will not be damaged.
11
AC reverse
protection
Prevent battery inverter AC current from being reversely input to
Bypass.
12
Bypass over current
protection
Built-in AC input overcurrent protection circuit breaker.
13
Battery input over
current protection
When the discharge output current of the battery is greater than the
maximum value and lasts for 1 minute, the AC input would switched
to load.
14
Battery input
protection
When the battery is reversely connected or the inverter is short-
circuited, the battery input fuse in the inverter will blow out to
prevent the battery from being damaged or causing a fire.
15
Charge short
protection
When the external battery port is short-circuited in the PV or AC
charging state, the inverter will protect and stop the output current.